Datasheet summary
XL-100-HTS
Engineering summary from PDF text extraction for XL-100-HTS. Verify every value with the OEM datasheet.
Summary
Product identification
The Electropure™ EDI HTS product line offers High Temperature Stable EDI modules, including XL-HTS™ and EXL-HTS™ models, designed for pharmaceutical OEMs. These modules are hot water sanitizable up to 85°C / 185°F.
Available models and their nominal flow rates:
- EXL-810-HTS: 6.5-8.0 m³/h (28-35 gpm)
- EXL-710-HTS: 5.0-7.0 m³/h (22-30 gpm)
- EXL-610-HTS: 3.5-5.5 m³/h (15-24 gpm)
- EXL-510-HTS: 2.5-4.0 m³/h (10-18 gpm)
- XL-500-HTS: 1.3-2.5 m³/h (6-11 gpm)
- XL-400-HTS: 0.7-1.5 m³/h (2.5-7.0 gpm)
- XL-300-HTS: 300-1000 lph (1.5-4.5 gpm)
- XL-200-HTS: 100-300 lph (0.5-1.5 gpm)
- XL-100-HTS: 50-150 lph (0.2-0.7 gpm)
Key benefits and features include:
- Hot Water Sanitizable at 85°C / 185°F for 15 min up to 2 hrs.
- Rapid Heat/Cool Cycle — up to 160 cycles.
- New High Temperature FDA Urethane Materials.
- Pharmaceutical Stainless Steel (EXL option).
- Light, Compact, Easy to Ship and Handle.
- Continuous Process.
- Minimized operating cost.
- No hazardous waste, regeneration acid, or caustic.
- Flexible, modular, and reliable design.
- No concentrate recirculation or brine injection.
- Thin-Cell efficient technology.
- Thin-Concentrate non-scaling technology.
- Unique non-scaling electrode system.
- Patented Excellion™ membranes.
Operating limits
- Temperature (Operation): 5 to 45°C (40-113°F)
- Temperature (Sanitize): 72-85°C (162-185°F)
- Concentrate Flow Direction: Upward
- Feed Flow Direction: Upward
Feed water
Recommended parameters for optimum performance and maximum allowable limits for feed water:
| Parameter | Recommended for Optimum Performance | Maximum |
|---|---|---|
| Feedwater Conductivity Equivalent Including CO₂ | <9 μS/cm | <33 μS/cm |
| pH | 7.0 to 7.5 | 5 to 9.5 |
| Total Chlorine (as Cl₂) and Ozone (O₃) | ND | ND |
| Iron (Fe) | ND | <.01 ppm |
| Manganese (Mn) | ND | <.01 ppm |
| Sulfide (S²⁻) | ND | <.01 ppm |
| Total Hardness (as CaCO₃) | <0.5 ppm | <1 ppm |
| Total Silica (as SiO₂) | <0.2 ppm | <0.5 ppm |
| Total Organics (TOC as C) | ND | <0.5 ppm |
Mechanical / hydraulic
XL-HTS module dimensions (Width x Height x Depth): 22 cm x 56 cm x D (8.5 in x 22 in x D):
- XL-100-HTS: Depth: 17 cm (6.5 in), Weight: 24 kg (54 lb)
- XL-200-HTS: Depth: 19 cm (7.5 in), Weight: 28 kg (61 lb)
- XL-300-HTS: Depth: 26 cm (10 in), Weight: 33 kg (72 lb)
- XL-400-HTS: Depth: 29 cm (11.5 in), Weight: 36 kg (80 lb)
- XL-500-HTS: Depth: 37 cm (14.5 in), Weight: 44 kg (95 lb)