Back to 3M-Liqui-Cel® Membrane Contactors
3M logo

Datasheet summary

EXF Series 10 x 28

Engineering summary from PDF text extraction for EXF Series 10 x 28. Verify every value with the OEM datasheet.

Summary

Product identification

The 3M™ Liqui-Cel™ EXF-10x28 Series Membrane Contactor features an Extra-Flow with Center Baffle cartridge configuration.

Membrane Characteristics

  • Membrane Type:
    • X50 Fiber: Recommended for CO₂ removal from liquid and other gas transfer applications.
    • X40 Fiber: Recommended for O₂ removal from liquid and other gas transfer applications.
  • Membrane/Potting Material: Polypropylene / Epoxy

Operating limits

  • Liquid Flow Guidelines: 10 – 57 m³/hr (44 – 250 gpm)
  • Maximum Shellside LIQUID Working Temperature/Pressure:
    • X50 Fiber:
      • 5-50°C, 7.2 barg (41-122°F, 105 psig)
      • 70°C, 2.1 barg (158°F, 30 psig)
    • X40 Fiber:
      • 5-25°C, 9.3 barg (41-77°F, 135 psig)
      • 50°C, 7.2 barg (77-122°F, 105 psig)
      • 70°C, 2.1 barg (158°F, 30 psig)
    • Note: If no vacuum is used, 1.0 barg (15 psig) can be added to pressures above.
  • Maximum Applied Gas Pressure:
    • FRP Housing: 6.2 barg at 25°C (90 psig at 77°F)
    • 316 SS Housing: 9.0 barg at 25°C (130 psig at 77°F)
    • Note: Maximum applied gas pressure is for integrity testing at ambient temperatures. Normal operating pressures are typically lower.
  • Important Note: Liquid pressure should always exceed gas pressure.
  • Pressure Limits Basis: Pressures are based on fluid group 2 (other) liquids and gases per the European Union Pressure Equipment Directive 2014/68/EU.

Mechanical / hydraulic

Housing Characteristics

  • FRP: Fiber Reinforced Plastic (FRP) with PVDF for all wetted surfaces and FRP flanges.
  • 316L SS: 316L SS Vessel/CF3M SS End Caps. ≤ 32RA (0.8μm SI) on schedule 10S pipe per ASTM A312.

Flange Connections

  • Shellside (Liquid Inlet/Outlet):
    • FRP Housing:
      • 3 inch class 150 raised face flange per ANSI B16.5
      • 80A 10K flat face flange per JIS B2238
    • 316 SS Housing:
      • 3 inch class 150 raised face flange per ANSI B16.5
      • 80A 10K flat face flange per JIS B2238
      • 3 inch sanitary
  • Lumenside (Gas/Vacuum):
    • FRP Housing:
      • 1 inch class 150 raised face flange per ANSI B16.5
      • 50A 10K flat face flange per JIS B2238
    • 316 SS Housing:
      • 1 inch class 150 raised face flange per ANSI B16.5
      • 25A 10K flat face flange per JIS B2238
      • 1.5 inch sanitary

Priming Volume (approximate)

  • FRP Housing:
    • X50 Fiber: Shellside 26.1 L (6.9 gal), Lumenside 10.6 L (2.8 gal)
    • X40 Fiber: Shellside 26.3 L (7.0 gal), Lumenside 9.5 L (2.5 gal)
  • 316 SS Sanitary/316 SS ANSI Housing:
    • X50 Fiber: Shellside 24.3/24.9 L (6.4/6.6 gal), Lumenside 7.5/10.0 L (1.9/2.6 gal)
    • X40 Fiber: Shellside 24.5/25.6 L (6.5/6.8 gal), Lumenside 6.4/9.5 L (1.7/2.5 gal)

Weight (approximate)

  • Dry:
    • FRP Housing: 33 kg (73 lbs)
    • Stainless Steel Housing (ANSI/JIS): 76 kg (168 lbs)
    • Stainless Steel Housing (Sanitary): 81 kg (177 lbs)
  • Water-filled (shellside):
    • FRP Housing: 57 kg (126 lbs)
    • Stainless Steel Housing (ANSI/JIS): 99 kg (218 lbs)
    • Stainless Steel Housing (Sanitary): 107 kg (235 lbs)
  • Cartridge only – dry: 10 kg (23 lbs)

Dimensions

  • FRP Housing: Overall length 1186 mm (46.7 in), diameter 279 mm (11.0 in). These are nominal values for the PVDF-lined FRP housing.
  • 316L SS Housing: Diameter 273 mm (10.8 in). SS contactor uses a different end cap design. Sanitary connections are only available with 316 SS housing.

Mounting Kit A mounting kit with 2 cradles and 2 straps is available and sold separately. It supports horizontal or vertical mounting.

Seal Options

  • EPDM: All Purpose. 3M™ Liqui-Cel™ Membrane Contactors with EPDM Seals are tested and certified by WQA against NSF/ANSI 61.
  • FKM: High Purity/Electronics (Available on FRP housing only).

Regulatory

The product complies with the limits as set by (EU) 2015/863 amending Annex II to the Restriction on Hazardous Substances (RoHS) Directive (2011/65/EU).


Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions from the original OEM PDF datasheet. For contractual data, always refer to the specific OEM PDF revision used on your project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.