Summary
Product identification
- Product Name: 3M™ Liqui-Cel™ EXF-10x28 Industrial Series Membrane Contactor
- Cartridge Configuration: Industrial Use Extra-Flow with Center Baffle
- Overall Dimensions (nominal):
- Length: 1186 mm (46.7 in)
- Diameter: 279 mm (11.0 in)
- Weight (approximate):
- Dry: 33 kg (73 lbs)
- Water-filled (shellside): 57 kg (125 lbs)
- Cartridge only – dry: 10 kg (23 lbs)
- Priming Volume (approximate):
- Shellside: 26.1 L (6.9 gal)
- Lumenside: 10.6 L (2.8 gal)
Operating limits
- Liquid Flow Guidelines: 10 – 48 m³/hr (44 – 210 gpm)
- Maximum Shellside LIQUID Working Temperature/Pressure: 5-50°C, 4.1 barg (41-122°F, 60 psig)
- If no vacuum is used, 1.0 barg (15 psig) can be added to pressures above.
- Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F)
- Note: Maximum applied gas pressure is for integrity testing at ambient temperatures. Normal operating pressures are typically lower.
- Pressure Note: Liquid pressure should always exceed gas pressure.
- Performance Curves: Graphs are provided for Pressure Drop vs. Water Flow Rate, Free CO₂ Removal % vs. Water Flow Rate, and % Dissolved Oxygen Removal vs. Water Flow Rate. Curves represent nominal values, generated using water at 20°C. Characteristics may change under different operating conditions. See the official PDF for exact tabulated values and detailed test conditions.
Membrane Characteristics
- Membrane Type: X-IND Fiber
- Membrane/Potting Material: Polypropylene / Epoxy
Mechanical / hydraulic
- Housing Characteristics Material: Fiber Reinforced Plastic (FRP) for Industrial Use
- Exterior finish is gray.
- Flange Connections:
- Shellside (Liquid Inlet/Outlet): 3 inch class 150 raised face flange per ANSI B16.5; 80A at 10K flat face flange per JIS B2238
- Lumenside: 1 inch class 150 raised face flange per ANSI B16.5; 50A at 10K flat face flange per JIS B2238
- Seal Options Material: EPDM (General Purpose applications)
- Mounting Kit: A Mounting Kit with 2 cradles and 2 straps is available and sold separately. It will hold the contactor horizontally or vertically.
Regulatory
- Complies with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. For contractual purposes, always refer to the specific OEM PDF revision used on your project.