Back to 3M-Liqui-Cel® Membrane Contactors
3M logo

Datasheet summary

EXF Series 14 x 28

Engineering summary from PDF text extraction for EXF Series 14 x 28. Verify every value with the OEM datasheet.

Summary

Product identification

The 3M™ Liqui-Cel™ EXF-14x28 Series Membrane Contactor features an Extra-Flow with Center Baffle cartridge configuration.

  • X50 Fiber: Recommended for CO₂ removal from liquid and other gas transfer applications.
  • X40 Fiber: Recommended for O₂ removal from liquid and other gas transfer applications.

Mechanical / hydraulic

  • Dimensions:
    • Overall length (with Nylon End Caps): 1156 mm (45.5 in)
    • Overall length (with Engineered Thermoplastic End Caps): 1158 mm (45.6 in)
    • Diameter (from diagram): 356 mm (14.0 in)
    • Additional dimension (from diagram): 298 mm (11.7 in)
  • Weight (approximate):
    • With Nylon End Caps:
      • Dry: 62 kg (136 lbs)
      • Water-filled (shellside): 97 kg (213 lbs)
    • With Engineered Thermoplastic End Caps:
      • Dry: 54 kg (118 lbs)
      • Water-filled (shellside): 89 kg (196 lbs)
  • Liquid Flow Guidelines: 16 – 91 m³/hr (70 – 400 gpm)
  • Pressure Guidelines (X50 or X40 Fiber):
    • Maximum Shellside LIQUID Working Temperature/Pressure:
      • 5-25°C, 7.2 barg (41-77°F, 105 psig)
      • 50°C, 2.1 barg (122°F, 30 psig)
    • If no vacuum is used, 1.0 barg (15 psig) can be added to pressures above.
    • Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F)
    • Note: Liquid pressure should always exceed gas pressure. Maximum applied gas pressure is for integrity testing; normal operating pressures are typically lower.
  • Flange Connections:
    • Shellside (Liquid Inlet/Outlet):
      • 4 inch class 150 raised face flange per ANSI B16.5
      • 100A 10K raised face flange per JIS B2238
    • Lumenside:
      • 2 inch class 150 raised face flange per ANSI B16.5
      • 50A 10K flat face flange per JIS B2238

Materials

  • Membrane Type: X50 Fiber, X40 Fiber
  • Membrane/Potting Material: Polypropylene / Epoxy
  • End Caps: Nylon, Engineered Thermoplastic
  • Housing Vessel: PVC
  • Flange Backing Rings: SMC (Sheet Molded Compound)
  • Seal Options: EPDM (General Purpose)

Priming Volume (approximate)

  • With Nylon End Caps:
    • X50 Fiber:
      • Shellside: 33.5 L (8.8 gal)
      • Lumenside: 21.7 L (5.7 gal)
    • X40 Fiber:
      • Shellside: 35.5 L (9.3 gal)
      • Lumenside: 20.9 L (5.5 gal)
  • With Engineered Thermoplastic End Caps:
    • X50 Fiber:
      • Shellside: 35.4 L (9.3 gal)
      • Lumenside: 23.8 L (6.3 gal)
    • X40 Fiber:
      • Shellside: 37.3 L (9.9 gal)
      • Lumenside: 23.0 L (6.1 gal)

Regulatory

  • Complies with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.
  • Tested and certified by WQA against NSF/ANSI 61.

Other Features

  • Mounting Kit: A mounting kit with 2 cradles and 2 straps is available and sold separately. It supports horizontal or vertical contactor orientation.

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions found in the official PDF. Contractual data must always match the OEM PDF revision used on the project.