Back to 3M-Liqui-Cel® Membrane Contactors
3M logo

Datasheet summary

EXF Series 14 x 40

Engineering summary from PDF text extraction for EXF Series 14 x 40. Verify every value with the OEM datasheet.

Summary

Product identification

The 3M™ Liqui-Cel™ EXF-14x40 Series is a membrane contactor designed for O₂ removal from liquid and other gas transfer applications.

Operating limits

  • Liquid Flow Guidelines: 16 – 125 m³/hr (70 – 550 gpm)
  • Maximum Shellside LIQUID Working Temperature/Pressure:
    • 5-25°C, 7.2 barg (41-77°F, 105 psig)
    • 50°C, 2.1 barg (122°F, 30 psig)
    • If no vacuum is used, 1.0 barg (15 psig) can be added to pressures above.
  • Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F)
    • Note: Maximum applied gas pressure is for integrity testing at ambient temperatures; normal operating pressures are typically lower.
  • Liquid pressure should always exceed gas pressure.
  • Pressures are based on fluid group 2 (other) liquids and gases per the European Union Pressure Equipment Directive 2014/68/EU. See Operating Guide for pressure limits in the European Union with fluid group 1 (hazardous) liquids and gases. Also, see Operating Guide for complete temperature/pressure limits for housings and membrane.

Mechanical / hydraulic

  • Dimensions:
    • Overall length with engineered thermoplastic end caps: 1466 mm (57.7 in).
    • Other dimensions shown in diagram: 297 mm (11.7 in), 356 mm (14.0 in).
    • All dimensions are nominal values.
  • Membrane Characteristics:
    • Cartridge Configuration: Extra-Flow with Center Baffle
    • Membrane Type: X40 Fiber
    • Membrane/Potting Material: Polypropylene / Epoxy
  • Priming Volume (approximate):
    • With Nylon End Caps:
      • Shellside: 51.3 L (13.5 gal)
      • Lumenside: 23.8 L (6.3 gal)
    • With Engineered Thermoplastic End Caps:
      • Shellside: 53.2 L (14.1 gal)
      • Lumenside: 25.9 L (6.9 gal)
  • Housing Characteristics:
    • Housing Material: PVC Vessel with Engineered Thermoplastic or Nylon End Caps
    • Flange Backing Rings: SMC (Sheet Molded Compound)
  • Flange Connections:
    • Shellside (Liquid Inlet/Outlet):
      • 4 inch class 150 raised face flange per ANSI B16.5
      • 100A at 10K raised face flange per JIS B2238
    • Lumenside:
      • 2 inch class 150 raised face flange per ANSI B16.5
      • 50A at 10K flat face flange per JIS B2238
  • Seal Options:
    • Material: EPDM (ANSI / NSF 61)
    • Applications: All Purpose
  • Weight (approximate):
    • With Nylon End Caps:
      • Dry: 72 kg (160 lbs)
      • Water-filled: 124 kg (273 lbs)
    • With Engineered Thermoplastic End Caps:
      • Dry: 64 kg (141 lbs)
      • Water-filled: 116 kg (256 lbs)
  • Mounting: A Mounting Kit with 2 cradles and 2 straps is available and sold separately. It will hold the contactor horizontally or vertically.

Regulatory

  • Complies with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.
  • Tested and certified by WQA against NSF/ANSI 61.

Performance Characteristics

Performance curves for O₂ removal and pressure drop are available, generated using water at 20°C. O₂ removal test conditions involved X40 membrane in N₂-vacuum combo mode, with vacuum at 50 torr and N₂ at 0.8 scfm. Characteristics may change under different operating conditions. See the official PDF for exact tabulated values and performance curves.


Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original PDF datasheet. Contractual data should always match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.