Back to 3M-Liqui-Cel® Membrane Contactors
3M logo

Datasheet summary

EXF Series 6 x 28

Engineering summary from PDF text extraction for EXF Series 6 x 28. Verify every value with the OEM datasheet.

Summary

Product identification

The product is a 3M™ Liqui-Cel™ EXF-6x28 Series Membrane Contactor.

  • Cartridge Configuration: Extra-Flow with Center Baffle

Membrane Characteristics

  • Membrane Type: X50 Fiber, X40 Fiber
  • Membrane/Potting Material: Polypropylene/Epoxy
  • Recommended Use:
    • X50 Fiber: For CO₂ removal from liquid and other gas transfer applications.
    • X40 Fiber: For O₂ removal from liquid and other gas transfer applications.

Operating limits

  • Liquid Flow Guidelines: 1 – 11 m³/hr (5 – 50 gpm)
  • Priming Volume (approximate):
    • X50 Fiber:
      • Shellside: 6.7 L (1.8 gal)
      • Lumenside: 2.6 L (0.7 gal)
    • X40 Fiber:
      • Shellside: 6.7 L (1.8 gal)
      • Lumenside: 2.3 L (0.6 gal)
  • Pressure Guidelines:
    • Maximum Shellside LIQUID Working Temperature/Pressure:
      • X50 Fiber:
        • 5-25°C: 7.2 barg (41-77°F, 105 psig)
        • 60°C: 2.1 barg (140°F, 30 psig)
      • X40 Fiber:
        • 5-25°C: 7.2 barg (41-77°F, 105 psig)
        • 70°C: 2.1 barg (158°F, 30 psig)
    • If no vacuum is used, 1 barg (15 psig) can be added to the pressures above.
    • Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F)
      • Note: This is for integrity testing at ambient temperatures; normal operating pressures are typically lower.
    • Important Note: Liquid pressure should always exceed gas pressure.
    • See the Operating Guide for complete temperature/pressure limits for housings and membrane.

Mechanical / hydraulic

  • Housing Material: ABS
  • Flange Connections:
    • Shellside (Wetted surface):
      • 2 inch class 150 raised face flange per ANSI B16.5
      • 50A at 10K flat face flange per JIS B2238
    • Lumenside:
      • 1 inch class 150 raised face flange per ANSI B16.5
      • 25A at 10K flat face flange per JIS B2238
  • Weight (approximate):
    • Dry: 10 kg (23 lbs)
    • Water-filled (shellside): 17 kg (38 lbs)
  • Nominal Dimensions:
    • 1009 mm (39.7 in)
    • 168 mm (6.6 in)
    • 765 mm (30.1 in)
    • See the full housing drawing on 3M.com/Liqui-Cel for additional details.

Regulatory

  • Complies with the limits set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.
  • Constructed of FDA CFR title 21 compliant materials for wetted parts only, with non-alcoholic liquids at ambient temperatures.

Performance Curves

The datasheet includes graphs illustrating typical dissolved oxygen removal percentage and free CO₂ removal percentage versus water flow rate, as well as pressure drop versus water flow rate for one and two contactors.

  • Test Condition O₂ Removal (X40 membrane at 20°C): N₂ Combo mode, vacuum 75 mm Hg, N₂ sweep: 1.4 L/min (0.05 scfm).
  • Test Condition CO₂ Removal (X50 membrane at 20°C): Air Combo mode, air sweep: 0.25 G/L, vacuum: 150 torr.
  • See the official PDF for exact tabulated values and detailed curve characteristics.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.