Summary

Product identification

  • 3M™ Liqui-Cel™ EXF-8x20 Series Membrane Contactor

Mechanical / hydraulic

  • Dimensions (nominal)
    • 852 mm (33.5 in)
    • 298 mm (11.7 in)
    • See full housing drawing on 3M.com/Liqui-Cel for additional details.
  • Weight (approximate)
    • Dry: 37 kg (82 lbs)
    • Water-filled (shellside): 44 kg (96 lbs)
  • Cartridge Configuration: Extra-Flow with Center Baffle
  • Membrane Type: X40 Fiber
  • Membrane/Potting Material: Polypropylene / Epoxy
  • Housing Material: 316L SS Housing, ABS Cartridge Shell
  • Port Connections
    • Shellside (Liquid Inlet/Outlet): 2 inch sanitary
    • Lumenside: 2 inch sanitary
  • Seal Options
    • Material: EPDM
    • Applications: All Purpose
  • Priming Volume (approximate)
    • Shellside: 6.3 L (1.7 gal)
    • Lumenside: 9.5 L (2.5 gal)

Operating limits

  • Liquid Flow Guidelines: 1 – 11 m³/hr (5 – 50 gpm)
  • Maximum Shellside LIQUID Working Temperature/Pressure
    • 25°C (77°F), 9.3 barg (135 psig)
    • 50°C (122°F), 3.1 barg (45 psig)
    • 70°C (158°F), 1.1 barg (15 psig)
    • If no vacuum is used, 1.0 barg (15 psig) can be added to pressures above.
  • Maximum Applied Gas Pressure: 5.2 barg at 25°C (75 psig at 77°F)
    • Maximum applied gas pressure is for integrity testing at ambient temperatures. Normal operating pressures are typically lower.
  • Note: Liquid pressure should always exceed gas pressure.
  • See Operating Guide for complete temperature/pressure limits for housings and membrane.

Applications

  • Recommended for O₂ and CO₂ removal from liquids, carbonation, and other gas transfer applications.

Regulatory

  • Complies with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.
  • Constructed of FDA CFR title 21 compliant materials for wetted parts only.

Performance Characteristics

  • Curves are provided for O₂ removal, CO₂ removal, and pressure drop versus water flow rate. Test conditions for O₂ removal involved N₂-vacuum combo mode with water at 20°C, vacuum at 50 mm Hg absolute, and N₂ sweep at 0.25 scfm. Test conditions for CO₂ removal involved air sweep mode with water at 25°C and air sweep at 10 scfm.
  • See the official PDF for exact tabulated values and detailed performance curves.

Disclaimer: This summary is based on the provided text extract and may not include all figures, footnotes, or the latest revisions. Contractual data for any project must match the OEM PDF revision used on that specific project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.