Datasheet summary
EXF Series 8 x 20 Stainless steel housing
Engineering summary from PDF text extraction for EXF Series 8 x 20 Stainless steel housing. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: 3M™ Liqui-Cel™ EXF-8x20 Industrial Series Membrane Contactor
- Membrane Type: XIND Fiber
- Membrane/Potting Material: Polypropylene / Epoxy
- Cartridge Configuration: Extra-Flow with Center Baffle
- Primary Application: CO₂ removal from liquid and other gas transfer applications
Operating limits
- Liquid Flow Guidelines: 1 – 11 m³/hr (5 – 50 gpm)
- Maximum Shellside LIQUID Working Temperature/Pressure:
- 25°C, 4.8 barg (77°F, 70 psig)
- 40°C, 2.1 barg (104°F, 30 psig)
- Note: If no vacuum is used, 1.0 barg (15 psig) can be added to pressures above.
- Note: If operating using air sweep, the liquid or air temperature should not exceed 30°C for any length of time. Exceeding 30°C will reduce contactor life.
- Maximum Applied Gas Pressure: 2.1 barg at 25°C (30 psig at 77°F) (for integrity testing at ambient temperatures; normal operating pressures are typically lower).
- Pressure Guideline: Liquid pressure should always exceed gas pressure.
Mechanical / hydraulic
- Nominal Dimensions:
- Length: 663 mm (26.1 in)
- Diameter: 219 mm (8.6 in)
- Other dimension: 64 mm (2.5 in)
- Priming Volume (approximate):
- Shellside: 6.7 L (1.8 gal)
- Lumenside: 5.2 L (1.4 gal)
- Housing Material: PVC
- End Caps Material: Engineering thermoplastic
- Port Connections:
- Shellside (Liquid Inlet/Outlet):
- 1 Inch Female NPT
- 1.5 Inch Grooved pipe fitting
- Note: Both options are standard on 1 end cap.
- Lumenside: 1 Inch Female NPT
- Shellside (Liquid Inlet/Outlet):
- Weight (approximate):
- Dry: 13 kg (28 lbs)
- Water-filled (shellside): 19 kg (43 lbs)
- Pressure Drop: Curves are provided in the source document for Water Flow Rate vs. Pressure Drop using water at 25°C, but specific numerical values are not listed in the text. See the official PDF for exact tabulated values.
Regulatory
- Complies with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions from the original OEM PDF. For contractual data, always refer to the specific OEM PDF revision used on the project.