Datasheet summary
EXF Series 8 x 80
Engineering summary from PDF text extraction for EXF Series 8 x 80. Verify every value with the OEM datasheet.
Summary
Product identification
The 3M™ Liqui-Cel™ EXF-8x80 Series Membrane Contactor features an Extra-Flow with Center Baffle cartridge configuration. It utilizes X40 Fiber membrane, recommended for high pressure O₂ removal and other gas transfer applications.
- Membrane Type: X40 Fiber
- Membrane/Potting Material: Polypropylene / Epoxy
- Housing Characteristics Material: Fiber Reinforced Plastic (FRP), FRP Vessel Code-rated to ASME BPVC Section X
Operating limits
- Liquid Flow Guidelines: 7 – 28 m³/hr (30 – 125 gpm)
- Maximum Shellside LIQUID Working Temperature/Pressure:
- 5-25°C, 19.7 barg (41-86°F, 285 psig)
- 60°C, 12.0 barg (140°F, 175 psig)
- Note: If no vacuum is used, 1.0 barg (15 psig) can be added to pressures above.
- Maximum Applied Gas Pressure: 2.1 barg at 25°C (30 psig at 77°F) (for integrity testing at ambient temperatures; normal operating pressures are typically lower).
- Important Note: Liquid pressure should always exceed gas pressure.
Mechanical / hydraulic
All dimensions are nominal values.
- Overall Length: 2518 mm (99.2 in)
- Nominal Diameter (max): 255 mm (10.0 in)
- Nominal Diameter (other): 212 mm (8.3 in)
- Internal Length: 2210 mm (87.0 in)
- Priming Volume (approximate):
- Shellside: 30.3 L (8.0 gal)
- Lumenside: 19.7 L (5.2 gal)
- Connections:
- Shellside (Liquid Inlet/Outlet): 1.5 Inch Grooved pipe fitting
- Lumenside: 1.5 Inch Grooved pipe fitting
- Seal Options Material: EPDM (All Purpose)
- Weight (approximate):
- Dry: 52 kg (115 lbs)
- Water-filled (shellside): 89 kg (196 lbs)
Performance curves for O₂ removal and pressure drop with water flow rate are available in the official PDF, representing nominal values with an FRP vessel using water at 20°C.
Regulatory
- Complies with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.
Disclaimer: This summary is based on the provided text extract. The original OEM PDF datasheet may contain additional figures, footnotes, and revisions not present here. Contractual data must match the specific OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.