Summary

Product identification

3M™ Liqui-Cel™ MM-0.5x1 Series Membrane Contactor

Operating limits

  • Liquid Flow Guidelines: 5 – 30 ml/min (Liquid must flow on the shellside)
  • Maximum Shellside LIQUID Working Temperature/Pressure:
    • 5-25°C, 3.1 barg (41-77°F, 45 psig)
    • 40°C, 1.0 barg (104°F, 15 psig)
    • Note: Liquid pressure should always exceed gas pressure.

Mechanical / hydraulic

  • Dimensions (nominal values):
    • 55 mm (2.2 in)
    • 55 mm (2.2 in)
    • 30 mm (1.2 in)
    • 13 mm (0.5 in)
    • See full housing drawing on 3M.com/Liqui-Cel for additional details.
  • Typical Properties:
    • Membrane Type: X50
    • Membrane/Potting Material: Polypropylene / Epoxy
    • Cartridge Configuration: No Baffle Membrane Array Design
    • Priming Volume (approximate) - Shellside: 3.5 ml
  • Housing Characteristics:
    • Material: Polycarbonate
    • Connections:
      • Shellside (Liquid Inlet/Outlet): 1/4 inch Straight Tube
      • Lumenside (vacuum): 1/4 inch Straight Tube
    • Weight (approximate) - Dry: 10 grams
  • Pressure Drop:
    • In all flow rates up to 30 ml/min, the pressure drop is < 0.014 bard (0.2 psid).

Regulatory

  • Complies with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.
  • Constructed of FDA CFR title 21 compliant materials for wetted parts only at ambient temperatures.