Back to 3M-Liqui-Cel® Membrane Contactors
3M logo

Datasheet summary

SP Series 2.5 x 8

Engineering summary from PDF text extraction for SP Series 2.5 x 8. Verify every value with the OEM datasheet.

Summary

Product identification

3M™ Liqui-Cel™ SP-2.5x8 Series Membrane Contactor

Membrane Characteristics

  • Cartridge Configuration: Extra-Flow with Center Baffle
  • Membrane/Potting Material: Polyolefin / Polyethylene
  • Priming Volume:
    • Shellside: 0.23 liters (0.06 gal)
    • Lumenside: 0.09 liters (0.02 gal)

Operating limits

  • Liquid Flow Guidelines (Shellside): 0.1 – 0.7 m³/hr (0.5 – 3 gpm)
    • Liquid must flow on the shellside.
  • Maximum Shellside LIQUID Working Temperature/Pressure:
    • 5-25°C, 4.1 barg (41-77°F, 60 psig)
    • 50°C, 1.0 barg (122°F, 15 psig)
    • Note: If no vacuum is used, 1.0 barg (15 psig) can be added to pressures above.
  • Maximum Applied Gas Pressure: 4.1 barg at 25°C (60 psig at 77°F)
    • Max applied gas pressure is for integrity testing at ambient temperatures. Normal operating pressures are typically lower.
  • General Note: Liquid pressure should always exceed gas pressure.
  • Operating Guide: See Operating Guide for complete listing of temp/pressure limits for housings and membrane.

Housing Characteristics

  • Material: Polypropylene
  • Flange Connections:
    • Shellside (Liquid Inlet/Outlet):
      • ¼ inch NPT female
      • 3/8 inch Flaretek® (nut included)
      • ½ inch Flaretek® (nut included)
    • Lumenside:
      • ¼ inch NPT female
  • Seal Options:
    • Fluoroelastomer: General Purpose
    • Perfluoroelastomer: Ultra Pure Water
  • Weight (approximate):
    • Dry: 0.5 kg (1.1 lbs)
    • Water-Filled (shellside): 0.7 kg (1.6 lbs)

Mechanical / hydraulic

  • Dimensions (nominal values for contactors with NPT connections):
    • Diameter: 77 mm (3.1 in), 67 mm (2.6 in)
    • Length: 277 mm (10.9 in), 255 mm (10.0 in)
    • Note: Overall length with Flaretek connections increases. Refer to 3M.com/Liqui-Cel for detailed housing drawings.

Regulatory

  • Complies with the limits as set by RoHS Directive 2011/65/EU Annex II; recasting 2002/95/EC.
  • Constructed of FDA CFR title 21 compliant materials for wetted parts only at ambient temperatures.

Performance Graphs

The datasheet includes graphs illustrating performance characteristics:

  • Pressure Drop vs. Water Flow Rate: Shows how pressure drop (in bard and psid) changes with increasing water flow rate (in m³/hr and gpm).
  • Oxygen Removal % vs. Water Flow Rate: Shows the percentage of oxygen removal relative to water flow rate (in m³/hr and gpm) at different vacuum levels (50 torr, 75 torr).
  • Test condition for O₂ Removal: Vacuum mode with water at 20°C. Characteristics may change under different operating conditions.

See the official PDF for exact tabulated values and detailed curve data.


Disclaimer: This summary is based on the extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.