Datasheet summary
LEWATIT® MP 62
Engineering summary from PDF text extraction for LEWATIT® MP 62. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Name: Lewatit® MP 62
- Type: Weakly basic, macroporous anion exchange resin with tertiary amine groups (monofunctional)
- Structure: Macroporous, Styrenic matrix
- Appearance: Beige, opaque
- Delivery Form: Free base
Operating limits
- pH range (operation during exhaustion): 0-8
- pH range (stability): 0-14
- Operating temperature (max): 130 °C
- Storage temperature range: -20 - +40 °C
- Storage time (after delivery) (max): 2 years
Feed water / Application
- Demineralization of water for industrial steam generation (co-current or counter-current systems like Lewatit® WS System, Lewatit® Liftbed System or Lewatit® Rinsebed System)
- Removal of organic matter, especially from surface water
- Deacidification of organic process streams
Electrical
N/A
Mechanical / Hydraulic
- Uniformity coefficient (max): 1.8
- Range of size for >90 vol% of all beads: 0.315 - 1.25 mm
- Effective size (d10): 0.41 - 0.53 mm
- Bulk density for shipment (+/- 5%): 620 g/L
- Density (approx.): 1.02 g/mL
- Water retention (delivery form) (approx. weight %): 50-55 %
- Volume change (free base - Cl-) (max. approx. %): 45 %
- Bed depth for single column (min.): 800 mm
- Back wash bed expansion per m/h (20°C): 30 %
- Specific pressure loss (15°C): 1.1 kPa*h/m²
- Max. pressure loss during operation: 250 kPa
- Specific flow rate (max): 40 BV/h
Regeneration
- NaOH regeneration concentration (approx. wt. %): 2-6 %
- NaOH regeneration quantity (co-current) (min. g/L resin): 80 g/L resin
- NaOH regeneration quantity (counter-current) (min. g/L resin): 50 g/L resin
- Regeneration contact time (min. minutes): 30 minutes
- Slow rinse at regeneration flow rate (min. BV): 2 BV
- Fast rinse at service flow rate (min. BV): 4 BV
Chemical Properties
- Total capacity (delivery form) (min.): 1.7 eq/L
Safety and Storage
- Safety: Strong oxidants (e.g., nitric acid) can cause violent reactions. Observe the Safety Data Sheet.
- Storage: Store under roof in dry conditions, above freezing point, and out of direct sunlight. If frozen, thaw gradually at ambient temperature.
- Disposal: Follow European waste nomenclature for disposal in the European Community.