Back to Lanxess LEWATIT
Lanxess logo

Datasheet summary

LEWATIT® MP 62

Engineering summary from PDF text extraction for LEWATIT® MP 62. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: Lewatit® MP 62
  • Type: Weakly basic, macroporous anion exchange resin with tertiary amine groups (monofunctional)
  • Structure: Macroporous, Styrenic matrix
  • Appearance: Beige, opaque
  • Delivery Form: Free base

Operating limits

  • pH range (operation during exhaustion): 0-8
  • pH range (stability): 0-14
  • Operating temperature (max): 130 °C
  • Storage temperature range: -20 - +40 °C
  • Storage time (after delivery) (max): 2 years

Feed water / Application

  • Demineralization of water for industrial steam generation (co-current or counter-current systems like Lewatit® WS System, Lewatit® Liftbed System or Lewatit® Rinsebed System)
  • Removal of organic matter, especially from surface water
  • Deacidification of organic process streams

Electrical

N/A

Mechanical / Hydraulic

  • Uniformity coefficient (max): 1.8
  • Range of size for >90 vol% of all beads: 0.315 - 1.25 mm
  • Effective size (d10): 0.41 - 0.53 mm
  • Bulk density for shipment (+/- 5%): 620 g/L
  • Density (approx.): 1.02 g/mL
  • Water retention (delivery form) (approx. weight %): 50-55 %
  • Volume change (free base - Cl-) (max. approx. %): 45 %
  • Bed depth for single column (min.): 800 mm
  • Back wash bed expansion per m/h (20°C): 30 %
  • Specific pressure loss (15°C): 1.1 kPa*h/m²
  • Max. pressure loss during operation: 250 kPa
  • Specific flow rate (max): 40 BV/h

Regeneration

  • NaOH regeneration concentration (approx. wt. %): 2-6 %
  • NaOH regeneration quantity (co-current) (min. g/L resin): 80 g/L resin
  • NaOH regeneration quantity (counter-current) (min. g/L resin): 50 g/L resin
  • Regeneration contact time (min. minutes): 30 minutes
  • Slow rinse at regeneration flow rate (min. BV): 2 BV
  • Fast rinse at service flow rate (min. BV): 4 BV

Chemical Properties

  • Total capacity (delivery form) (min.): 1.7 eq/L

Safety and Storage

  • Safety: Strong oxidants (e.g., nitric acid) can cause violent reactions. Observe the Safety Data Sheet.
  • Storage: Store under roof in dry conditions, above freezing point, and out of direct sunlight. If frozen, thaw gradually at ambient temperature.
  • Disposal: Follow European waste nomenclature for disposal in the European Community.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.