Amberjet 1200 Na

Engineering summary from PDF text extraction for Amberjet 1200 Na. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: AMBERJET™ 1200 Na
  • Product Type: Industrial Grade Strong Acid Cation Exchanger
  • Matrix: Styrene divinylbenzene copolymer
  • Functional group: Sulfonate
  • Ionic form as shipped: Na⁺

Performance

Operating capacity and ionic leakage depend on water analysis, temperature, and regenerant level.

Typical Properties

  • Physical form: Amber spherical beads
  • Total exchange capacity: ≥ 2.00 eq/L (Na⁺ form) [1]
  • Moisture holding capacity: 43 to 47% (Na⁺ form) [1]
  • Shipping weight: 850 g/L
  • Specific gravity: 1.26 to 1.30 (Na⁺ form)
  • Particle size:
    • Uniformity coefficient: ≤ 1.2 [1]
    • Harmonic mean size: 620 ± 50 µm
    • Fines content: < 0.300 mm : 0.1% max [1]
  • Maximum reversible swelling: Na⁺ ⇌ H⁺ : 10%

[1] Contractual value. Test methods are available on request.

Suggested Operating Conditions

  • Maximum operating temperature: 135°C
  • Minimum bed depth: 800 mm
  • Service flow rate: 5 to 50 BV*/h
  • Maximum service velocity: 60 m/h

Regeneration

RegenerantLevel (g/L)Concentration (%)Minimum contact timeRinse (Slow/Fast)
NaCl50 to 2401020 minutes2 BV / 1 to 3 BV
HCl40 to 1504 to 1020 minutes2 BV at regen. flow / 1-3 BV at service flow
H₂SO₄40 to 2001 to 820 minutes2 BV at regen. flow / 1-3 BV at service flow
  • 1 BV (Bed Volume) = 1 m³ solution per m³ resin.

Limits of Use

AMBERJET 1200 Na resin is suitable for industrial uses. For pharmaceutical, food processing, or potable water applications, users should consult Rohm and Haas.

Hydraulic Characteristics

Figure 1 (in the original document) shows bed expansion as a function of backwash flow rate and water temperature. Figure 2 (in the original document) shows pressure drop data as a function of service flow rate and water temperature. Pressure drop data are valid at the start of the service run with clear water and a correctly classified bed.