Datasheet summary
CSM RE2012-100
Engineering summary from PDF text extraction for CSM RE2012-100. Verify every value with the OEM datasheet.
Summary
Product identification
- Model Name: RE2012-100
- Application: RO element for residential use
- Certification: NSF/ANSI 58
- General Features:
- Permeate Flow Rate: 110 GPD (416 L/day)
- NaCl Rejection: 98% (Minimum 96%)
- Membrane Type: Thin-Film Composite
- Membrane Material: Polyamide (PA)
- Element Configuration: Spiral-Wound, Tape Wrapping
- Test Conditions (for stated performance):
- 200 mg/L NaCl solution
- 60 psig (0.41 MPa) applied pressure
- 15% recovery
- 77℉ (25℃)
- pH 6.5–7.0
- Performance data taken after 30 minutes of operation.
- Permeate flow rate for each element may vary +20 / -20%.
- Minimum salt rejection is 96.0%.
- All elements are vacuum leak tested using the CSM integrity test.
- Elements can be supplied as dry or wet-type. Wet-tested elements are soaked in a preservative solution (1.0% food grade SBS) and vacuum sealed in a poly bag.
- All elements are individually boxed.
Operating limits
- Max. Operating Pressure: 150 psi (1.03 MPa)
- Max. Feed Flow Rate: 2 gpm (0.45 m³/hr)
- Max. Operating Temperature: 113°F (45°C)
- Operating pH Range: 2.0 – 11.0
- Max. Turbidity: 1.0 NTU
- Max. SDI (15 min): 3.0
- Max. Chlorine Concentration: < 0.1 mg/L
Mechanical / hydraulic
- Element Configuration: Spiral-Wound, Tape Wrapping
- Dimensions (RE2012-100):
- A: 0.67 inch (17 mm)
- B: 0.47 inch (12 mm)
- C: 11.73 inch (298 mm)
- D: 0.91 inch (23 mm)
- E: 1.89 inch (48 mm)
General Handling Procedures
- Elements contained in the boxes must be kept dry at room temperature (7–32°C; 40–95°F) and should not be stored in direct sunlight.
- For WET-TYPE, the preservative solution (1% sodium metabisulfite solution) is added to prohibit the growth of micro-organisms.
- Permeate from the first hour of operation should be discarded.
- Stabilized salt rejection is generally achieved within 1~48 hours of continuous use.
- Keep elements moist at all times after initial wetting.
- Avoid excessive pressure and flow spikes.
- Only use chemicals compatible with the membrane elements and components. Use of such chemicals may void the element limited warranty.
- Permeate pressure must always be equal or less than the feed/concentrate pressure. Damage caused by permeate back pressure voids the element limited warranty.
Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data and complete specifications, please refer to the specific OEM PDF revision used on your project.