Datasheet summary
WMC225 HYDRAcap60 UF module
Engineering summary from PDF text extraction for WMC225 HYDRAcap60 UF module. Verify every value with the OEM datasheet.
Summary
Product identification
The WMC225 HYDRAcap series consists of hollow fiber ultrafiltration modules designed for water treatment, as well as industrial and municipal wastewater reuse applications. These modules are effective in removing turbidity, suspended solids, viruses, and bacteria, offering outstanding pH and chlorine resistance. The series is available in different membrane surface areas.
- Module Types & Product Codes:
- WMC225 HYDRAcap60+ (Product-Code: SETUF0033)
- WMC225 HYDRAcap60 (Product-Code: SETUF0032)
- WMC225 HYDRAcap40 (Product-Code: SETUF0030)
Operating limits
Membrane Characteristics
- Membrane material: Modified PES
- Membrane fiber inner diameter: 0.8 mm (0.031”)
- Pore size: 0.02 µm
- Molecular Weight Cut Off (MWCO): 150 kDa (measured with dextran; estimation dependent on compound properties and test conditions)
- Filtration mode: Inside-Out; Vertical
- Operation mode: Dead-end or cross-flow
- Typical flux: 50 – 100 l/m²/h (30 – 60 gfd)
- Backwash flux: 100 – 250 l/m²/h (60 - 150 gfd)
Operating Conditions
- Max. system pressure: 3 bar (44 psi)
- Max. filtration transmembrane pressure: 1.5 bar (22 psi)
- Max. backwash pressure: 3 bar (44 psi)
- Max. active chlorine concentration: 500 ppm @ pH>10
- Max. cumulative active chlorine exposure: 250,000 ppm-hours @ pH>10
- Max. particle size: 200 µm
- Max. TSS: 200 ppm
- Max. turbidity: 100 NTU
- Max. Temperature during operation & cleaning: 40°C (104°F)
- pH range during operation: 2-12
- pH range during cleaning: 1-13
Mechanical / hydraulic
Materials of Construction
- Housing: PVC-U
- Internals:
- WMC225 HYDRAcap60+, WMC225 HYDRAcap60: MBS, PP, Noryl
- WMC225 HYDRAcap40: ABS, PP, PVC-U
- Potting: Epoxy resin
Dimensions and Membrane Surface Area
- Membrane Surface Area:
- WMC225 HYDRAcap60+: 56 m² (605 ft²)
- WMC225 HYDRAcap60: 46 m² (500 ft²)
- WMC225 HYDRAcap40: 30 m² (320 ft²)
- Module Length (L2.0):
- WMC225 HYDRAcap60+, WMC225 HYDRAcap60: 1600 mm (63”)
- WMC225 HYDRAcap40: 1092 mm (43”)
- Module Length (L2.1):
- WMC225 HYDRAcap60+, WMC225 HYDRAcap60: 1680 mm (66.13”)
- WMC225 HYDRAcap40: 1172 mm (46.13”)
- Module Length (L2.2):
- WMC225 HYDRAcap60+, WMC225 HYDRAcap60: 1710 mm (67.32”)
- WMC225 HYDRAcap40: 1202 mm (47.32”)
- Module Diameter (D2.0, D2.1): 60.3 mm (2.37”) for all types
Weight Information
- Empty weight Module including assembly components:
- WMC225 HYDRAcap60+: 36.5 kg (80 lbs)
- WMC225 HYDRAcap60: 34 kg (75 lbs)
- WMC225 HYDRAcap40: 25 kg (55 lbs)
- Filled module with assembly components:
- WMC225 HYDRAcap60+: 87 kg (191 lbs)
- WMC225 HYDRAcap60: 84 kg (185 lbs)
- WMC225 HYDRAcap40: 57 kg (126 lbs)
- Shipping weight per module (including preservative solution):
- WMC225 HYDRAcap60+: 43.5 kg (96 lbs)
- WMC225 HYDRAcap60: 41 kg (90 lbs)
- WMC225 HYDRAcap40: 29 kg (64 lbs)
- Shipping weight per crate (12 modules):
- WMC225 HYDRAcap60+: 505 kg (1113 lbs)
- WMC225 HYDRAcap60: 475 kg (1047 lbs)
- WMC225 HYDRAcap40: 360 kg (794 lbs)
Shipping Information
- Modules are individually packed in a vacuum-sealed plastic bag.
- Small quantities are shipped in separate cardboard boxes.
- Large shipments are loaded in wooden crates with a maximum of 12 modules per crate.
- Crate dimensions (L x W x H):
- WMC225 HYDRAcap40: 100 x 125 x 173 cm; 40 x 50 x 68 in
- WMC225 HYDRAcap60/60+: 100 x 125 x 191 cm; 40 x 50 x 75 in
Assembly Components
The module assembly includes the WMC225 HYDRAcap Module and the following components:
- Product end adapter
- O-ring #2-221 E70-150
- Plug Dead End
- O-ring #2-228 E70-150
- End cap Molded Ported
- End Cap Molded Nonported
- Plastic Clamp 4 Molded Endcap
- Washer D125-1A-M10-GALV
- Spring Washer D127B-M10-GALV
- Hex Bolt D931-M10x65-8.8zp
- Hex Nut D934-M10-Gr.08 zp
- O-ring #2-373 E70-150
Storage Information
New modules in original packaging can be stored for a maximum of 1 year from the shipping date. Storage conditions require a dry place, protected from sunlight or any heat source, at temperatures between 1 and 40°C (33 and 104°F). The ex-factory storage solution consists of 84wt% water, 15wt% glycerin, and 1wt% sodium metabisulfite.