Back to NX Filtration
NX Filtration logo

Datasheet summary

WMC225 HYDRAcap60 UF module

Engineering summary from PDF text extraction for WMC225 HYDRAcap60 UF module. Verify every value with the OEM datasheet.

Summary

Product identification

  • WMC225 HYDRAcap series hollow fiber ultrafiltration module
  • Designed for water treatment, industrial and municipal wastewater reuse
  • Excels in removing turbidity, suspended solids, virus, and bacteria
  • Offers outstanding pH and chlorine resistance
  • Available Module types:
    • WMC225 HYDRAcap60+ (Product-Code: SETUF0033)
    • WMC225 HYDRAcap60 (Product-Code: SETUF0032)
    • WMC225 HYDRAcap40 (Product-Code: SETUF0030)

Membrane characteristics

  • Membrane material: Modified PES
  • Membrane fiber inner diameter: 0.8 mm (0.031”)
  • Pore size: 0.02 μm
  • Molecular Weight Cut Off (MWCO): 150 kDa (Note: MWCO is an estimation as it depends on size, shape, charge and polarity of the compound being tested, as well as test conditions. Measured with dextran.)
  • Filtration mode: Inside-Out; Vertical
  • Operation mode: Dead-end or cross-flow

Operating limits

  • Max. system pressure: 3 bar (44 psi)
  • Max. filtration transmembrane pressure: 1.5 bar (22 psi)
  • Max. backwash pressure: 3 bar (44 psi)
  • Max. active chlorine concentration: 500 ppm @ pH>10
  • Max. cumulative active chlorine exposure: 250,000 ppm-hours @ pH>10
  • Max. Temperature during operation & cleaning: 40°C (104°F)
  • pH range during operation: 2-12
  • pH range during cleaning: 1-13

Feed water

  • Max. particle size: 200 μm
  • Max. TSS: 200 ppm
  • Max. turbidity: 100 NTU
  • Typical flux: 50 – 100 l/m²/h (30 – 60 gfd)
  • Backwash flux: 100 – 250 l/m²/h (60 - 150 gfd)

Mechanical / hydraulic

  • Materials of Construction:
    • Housing: PVC-U
    • Internals: MBS, PP, Noryl (for HYDRAcap60+, HYDRAcap60); ABS, PP, PVC-U (for HYDRAcap40)
    • Potting: Epoxy resin
  • Membrane Surface Area:
    • WMC225 HYDRAcap60+: 56 m² (605 ft²)
    • WMC225 HYDRAcap60: 46 m² (500 ft²)
    • WMC225 HYDRAcap40: 30 m² (320 ft²)
  • Dimensions:
    • Length (L2.0): 1600 mm (63”) for HYDRAcap60+/60; 1092 mm (43”) for HYDRAcap40
    • Length (L2.1): 1680 mm (66.13”) for HYDRAcap60+/60; 1172 mm (46.13”) for HYDRAcap40
    • Length (L2.2): 1710 mm (67.32”) for HYDRAcap60+/60; 1202 mm (47.32”) for HYDRAcap40
    • Diameter (D2.0, D2.1): 60.3 mm (2.37”) for all module types
  • Weight (Empty module including assembly components):
    • WMC225 HYDRAcap60+: 36.5 kg (80 lbs)
    • WMC225 HYDRAcap60: 34 kg (75 lbs)
    • WMC225 HYDRAcap40: 25 kg (55 lbs)
  • Weight (Filled module with assembly components):
    • WMC225 HYDRAcap60+: 87 kg (191 lbs)
    • WMC225 HYDRAcap60: 84 kg (185 lbs)
    • WMC225 HYDRAcap40: 57 kg (126 lbs)
  • Shipping Information:
    • Shipping weight per module:
      • WMC225 HYDRAcap60+: 43.5 kg (96 lbs)
      • WMC225 HYDRAcap60: 41 kg (90 lbs)
      • WMC225 HYDRAcap40: 29 kg (64 lbs)
    • Shipping weight per crate (12 modules):
      • WMC225 HYDRAcap60+: 505 kg (1113 lbs)
      • WMC225 HYDRAcap60: 475 kg (1047 lbs)
      • WMC225 HYDRAcap40: 360 kg (794 lbs)
    • Crate dimensions (L x W x H):
      • WMC225 HYDRAcap40: 100 x 125 x 173 cm; 40 x 50 x 68 in
      • WMC225 HYDRAcap60/60+: 100 x 125 x 191 cm; 40 x 50 x 75 in
  • Assembly Components: The module requires various assembly components including product end adapters, O-rings, plugs, end caps, plastic clamps, washers, bolts, and nuts. See the official PDF for exact tabulated values and part numbers.

Storage

  • New modules in original packaging can be stored for max. 1 year from shipping date.
  • Storage conditions: dry place, protected from sunlight or any heat source, at temperatures between 1 and 40°C (33 and 104°F).
  • Ex-factory storage solution: 84wt% water, 15wt% glycerin and 1wt% sodium metabisulfite.