Datasheet summary
SU-710P
Engineering summary from PDF text extraction for SU-710P. Verify every value with the OEM datasheet.
Summary
Product Identification
- Model: SU-710P
- Description: Low elution and easy to rinse RO element for Pure Water
- Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
- Element Configuration: Spiral Wound
Performance Specification
- Nominal Product Flow Rate: 8 m³/day (2100 GPD)
- Minimum Product Flow Rate: 7.3 m³/day (1850 GPD) for any single element
Test Conditions:
- Feed Water Pressure: 1.5 MPa (220 psi)
- Feed Water Temperature: 25 °C (77 °F)
- Feed Water Concentration: Pure water
- Brine Flow Rate: 20 L/min. (5.3 gpm)
- Feed Water pH: 6.5
Operating Limits
Recommended Design Conditions:
- Feed Water Pressure: 2.0 MPa (286 psi)
- Feed Water Temperature: 35 °C (95 °F)
- Feed Water Turbidity (SDI): 4 (measured according to ASTM D4189)
- Feed Water pH Range (Continuous Operation): 3 – 9
- Feed Water pH Range (Chemical Cleaning): 2 – 11
- Feed Flow Rate per Vessel: 50 L/min. (13 gpm)
- Brine Flow Rate per Vessel: 10 L/min. (2.6 gpm)
- Brine/Permeate Flow Ratio: 6 (at last element)
- Pressure Drop (per Element): 0.10 MPa (14 psi)
- Pressure Drop (per Vessel): 0.20 MPa (29 psi)
Maximum Operating Limits:
- Maximum Feed Water Pressure: 4.1 MPa (600 psi)
- Maximum Feed Water Temperature: 40 °C (104 °F)
Mechanical / Hydraulic
- Flow Direction: Feed (F) enters one end, Concentrated Brine (B) exits the other. Permeate exits separately.
- Dimensions: A length of 1016 mm is indicated in a diagram showing general element layout. Other dimensions are provided in the diagram but not explicitly tabulated in the text. All dimensions shown in millimeters.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. For contractual data, please refer to the official OEM PDF revision used on your project.