Datasheet summary
TMG20-370C
Engineering summary from PDF text extraction for TMG20-370C. Verify every value with the OEM datasheet.
Summary
Product Identification
- Type: Ultra low pressure BWRO
- Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
Test Conditions
The following conditions are used for performance rating:
- Feed Water Pressure: 110 psi (0.76 MPa)
- Feed Water Temperature: 77°F (25℃)
- Feed Water Concentration: 500 mg/l NaCl
- Recovery Rate: 15%
- Feed Water pH: 7
- Minimum Salt Rejection: 99.0%
Product Specifications
| Type | Nominal Product Flow Rate gpd (m³/d) | Feed Spacer Thickness mil | Nominal Salt Rejection % | Membrane Area ft² (m²) | Diameter Inch | Minimum Product Flow Rate gpd (m³/d) |
|---|---|---|---|---|---|---|
| TMG20-370C | 9,500 (36.0) | 34 | 99.5 | 370 (34) | 8” | 7,500 (28.4) |
| TMG20N-400C | 10,200 (38.6) | 34 | 99.5 | 400 (37) | 8” | 8,200 (31.0) |
| TMG20-440C | 11,300 (42.6) | 31 | 99.5 | 440 (41) | 8” | 9,000 (34.1) |
| TMG20-400C | 10,200 (38.6) | 28 | 99.5 | 400 (37) | 8” | 8,200 (31.0) |
Operating Limits
- Maximum Operating Pressure: 365 psi (2.5 MPa)
- Maximum Feed Water Temperature: 113°F (45℃)
- Maximum Feed Water SDI₁₅: 5
- Feed Water Chlorine Concentration: Not Detectable
- Feed Water pH Range, Continuous Operation: 2-11
- Feed Water pH Range, Chemical Cleaning: 1-12
- Maximum Pressure Drop per Element: 20 psi (0.14 MPa)
- Maximum Pressure Drop per Vessel: 60 psi (0.4 MPa)
Mechanical / Hydraulic
- All dimensions are shown in Inches (millimeter).
- Overall Length: 40 inches (1,016 mm)
- Diameter: 7.9 inches (201 mm)
- Permeate Tube Diameter: 1.125 inches (29 mm)
Storage and Handling
- All elements are wet tested, treated with a 1% by weight percent sodium bisulfite storage solution, and then vacuum packed in oxygen barrier bags.
- Alternatively, elements are treated with tested feed water solution and then vacuum packed in oxygen barrier bags with deoxidant inside.
- To prevent biological growth during short-term storage, shipment, or system shutdown, it is recommended that elements be immersed in a protective solution containing 500 - 1,000 ppm of sodium bisulfite (food grade) dissolved in permeate.
- Permeate from the first hour of operation shall be discarded.
Feed Water
- The presence of free chlorine and other oxidizing agents under certain conditions, such as heavy metals which act as oxidation catalysts, will cause unexpected oxidation of the membrane. It is strongly recommended to remove these oxidizing agents from the feed water before operating the RO system.
- The customer is fully responsible for the effects of chemicals that are incompatible with the elements. Their use will void the element Limited Warranty.
Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions present in the official PDF datasheet. For contractual data, please refer to the specific OEM PDF revision used for your project.
Official datasheet (PDF)