Back to Toray Membranes
Toray logo

Datasheet summary

TML20D-400

Engineering summary from PDF text extraction for TML20D-400. Verify every value with the OEM datasheet.

Summary

Product Identification

These are Brackish Water RO Elements of the TML20D series.

  • Membrane Type: Cross Linked Fully Aromatic Polyamide Composite
TypeProduct Flow Rate gpd (m³/d)Feed Spacer Thickness milSalt Rejection %Membrane Area ft² (m²)Diameter Inch
TML20D-3709,700 (36.7)2899.8370 (34)8”
TML20D-40010,500 (39.8)3199.8400 (37)8”
TML20DA40010,500 (39.8)3499.8400 (37)8”
TML20D-44011,500 (43.6)3499.8440 (41)8”

Operating Limits

  • Maximum Operating Pressure: 600 psi (4.1 MPa)
  • Maximum Feed Water Temperature: 113°F (45℃)
  • Maximum Feed Water SDI₁₅: 5
  • Feed Water Chlorine Concentration: <0.1 ppm
  • Feed Water pH Range, Continuous Operation: 2-11
  • Feed Water pH Range, Chemical Cleaning: 1-13
  • Maximum Pressure Drop per Element: 20 psi (0.14 MPa)
  • Maximum Pressure Drop per Vessel: 60 psi (0.4 MPa)

Feed Water

Test Conditions for performance rating:

  • Feed Water Pressure: 225 psi (1.55 MPa)
  • Feed Water Temperature: 77°F (25 ℃)
  • Feed Water Concentration: 2,000 mg/l NaCl
  • Recovery Rate: 15 %
  • Feed Water pH: 7

Product Water

  • Minimum Salt Rejection (under test conditions): 99.65 %

Mechanical / Hydraulic

All dimensions shown in Inches (millimeter).

  • Length: 40 (1,016)
  • Diameter: 7.9 (201)
  • Brine/Permeate connection inner diameter: 1.125 (29)

General Operating Notes

  • All elements are wet tested, treated with a 1% by weight percent sodium bisulfite storage solution, and then vacuum packed in oxygen barrier bags, or treated with tested feed water solution, and then vacuum packed in oxygen barrier bags with deoxidant inside.
  • To prevent biological growth during short term storage, shipment, or system shutdown, it is recommended that Toray elements be immersed in a protective solution containing 500 - 1,000 ppm of sodium bisulfite (food grade) dissolved in permeate.
  • The presence of free chlorine and other oxidizing agents under certain conditions, such as heavy metals which acts as oxidation catalyst in the feed water will cause unexpected oxidation of the membrane. It is strongly recommended to remove these oxidizing agents contained in feed water before operating RO system.
  • Permeate from the first hour of operation shall be discarded.
  • The customer is fully responsible for the effects of chemicals that are incompatible with the elements. Their use will void the element Limited Warranty.

Disclaimer: This summary is based on extracted text and may not include all figures, footnotes, or the latest revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.