Back to Veolia Membranes
Veolia logo

Datasheet summary

AD-90

Engineering summary from PDF text extraction for AD-90. Verify every value with the OEM datasheet.

Summary

Product identification

The AD Series consists of high rejection seawater reverse osmosis (RO) elements. These proprietary thin film reverse osmosis (TFM) elements are characterized by excellent sodium chloride (NaCl) rejection. They are selected when high quality permeate is demanded from seawater that is relatively high in Total Dissolved Solids (TDS). AD Series membrane chemistry provides excellent rejection characteristics when operated at seawater operating conditions (pressures exceeding 800 psi (5,516 kPa) and elevated temperatures).

Available Models

  • AD-90
    • Membrane type: Thin-film membrane (TFM)
    • Part number: 3056651
  • AD-400,34
    • Membrane type: Thin-film membrane (TFM)
    • Part number: 3056654
  • AD-440
    • Membrane type: Thin-film membrane (TFM)
    • Part number: 3056655

Product water

Performance Specifications

(Testing conditions: 32,000 mg/l NaCl & 5 mg/l boron solution at 800 psi (5,516 kPa) operating pressure, 77°F (25°C), pH 8.0 and 7% recovery. Average salt rejection after 24 hours of operation. Individual flow rate may vary ±20%.)

  • AD-90
    • Average permeate flow: 1375 gpd (5.2 m³/day)
    • Average NaCl rejection: 99.8%
    • Minimum NaCl rejection: 99.5%
    • Typical boron rejection: 95.0%
  • AD-400,34
    • Average permeate flow: 7000 gpd (26.5 m³/day)
    • Average NaCl rejection: 99.8%
    • Minimum NaCl rejection: 99.5%
    • Typical boron rejection: 95.0%
  • AD-440
    • Average permeate flow: 7700 gpd (29.2 m³/day)
    • Average NaCl rejection: 99.8%
    • Minimum NaCl rejection: 99.5%
    • Typical boron rejection: 95.0%

Operating limits

  • Typical operating pressure: 800 psi (5,516 kPa)
  • Maximum operating pressure: 1,200 psi (8,274 kPa)
  • Typical operating flux: 7-11 GFD (12-19 LMH)
  • Maximum temperature:
    • Continuous operation: 122°F (50°C)
    • Clean-In-Place (CIP): 122°F (50°C)
  • pH range:
    • Optimum rejection: 7.0-7.5
    • Continuous operation: 2.0-11.0
    • Clean-In-Place (CIP): 1.0-12.0
  • Maximum pressure drop:
    • Over an element: 15 psi (103 kPa)
    • Per housing: 50 psi (345 kPa)
  • Chlorine tolerance: 1,000+ ppm-hours (dechlorination recommended)

Feed water

  • NTU: < 1
  • SDI₁₅: < 5

Mechanical / hydraulic

Element Properties

  • AD-90
    • Active area: 90 ft² (8.4 m²)
    • Outer wrap: Fiberglass
  • AD-400,34
    • Active area: 400 ft² (37.2 m²)
    • Outer wrap: Fiberglass
  • AD-440
    • Active area: 440 ft² (40.9 m²)
    • Outer wrap: Fiberglass

Dimensions and Weights

(Dimensions are A (length), B (brine seal O.D.), C (element O.D.))

  • AD-90
    • Type: Male
    • Dimensions: 40.0 inches (101.6 cm) A; 0.75 inches (1.90 cm) B; 3.9 inches (9.9 cm) C
    • Boxed weight: 9 lbs (4 kg)
  • AD-400,34
    • Type: Female
    • Dimensions: 40.0 inches (101.6 cm) A; 1.125 inches (2.86 cm) B; 7.9 inches (20.1 cm) C
    • Boxed weight: 35 lbs (16 kg)
  • AD-440
    • Type: Female
    • Dimensions: 40.0 inches (101.6 cm) A; 1.125 inches (2.86 cm) B; 7.9 inches (20.1 cm) C
    • Boxed weight: 35 lbs (16 kg)

Disclaimer: This summary is based solely on the provided text extract. It may not include all figures, footnotes, or the latest revisions of the OEM PDF. Contractual data must match the specific OEM PDF revision used on the project.

Official datasheet (PDF)

PDF datasheet

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.