Summary

Product identification

The AK Series comprises Low Energy Brackish Water RO Elements, featuring A-series, thin-film membrane (TFM) technology designed for high flux and high sodium chloride rejection at low operating pressures. These elements allow for significant energy savings by achieving good rejection at operating pressures as low as 100 psi (689 kPa).

The specific model covered here is the AK2540TM.

  • Membrane: A-series, thin-film membrane (TFM)
  • Part Number: 1206802

Product water

Testing conditions for the following parameters: 500 ppm NaCl solution at 115 psi (793 kPa) operating pressure, 77°F (25°C), pH 7.5, and 15% recovery. Average salt rejection is measured after 24 hours of operation. Individual flow rate may vary ±20%.

  • Average Permeate Flow: 750 gpd (2.8 m³/day)
  • Average NaCl Rejection: 99.0%
  • Minimum NaCl Rejection: 98.0%

Operating limits

  • Typical Operating Pressure: 100 psi (689 kPa)
  • Typical Operating Flux: 10-20 GFD (15-35 LMH)
  • Maximum Operating Pressure: 600 psi (4,136 kPa)
  • Maximum Temperature:
    • Continuous operation: 122°F (50°C)
    • Clean In Place (CIP): 122°F (50°C)
  • pH Range:
    • Optimum rejection: 7.0-7.5
    • Continuous operation: 2.0-11.0
    • Clean In Place (CIP): 1.0-13.0
  • Maximum Pressure Drop:
    • Over an element: 15 psi (103 kPa)
    • Per housing: 50 psi (345 kPa)
  • Chlorine Tolerance: 1,000+ ppm x hours (dechlorination recommended)

Feed water

  • NTU: < 1
  • SDI₁₅: < 5

Mechanical / hydraulic

  • Membrane area: 27 ft² (2.5 m²)
  • Outer wrap: Tape
  • Type: Male
  • Dimensions (Inches (cm)):
    • A: 40.0 (101.6)
    • B: 0.75 (1.9)
    • C: 2.4 (6.1)
  • Boxed Weight: 5 lbs. (2.3 kg)

Note: 4040C elements do not feature a brine seal. Element properties and parameters are indicative numbers and may vary within normal element manufacturing tolerances.