CE4026F

Engineering summary from PDF text extraction for CE4026F. Verify every value with the OEM datasheet.

Summary

Product identification

This document describes Veolia C-Series Brackish Water Reverse Osmosis (RO) Elements, specifically the CE Series. These elements use a C-Series Cellulose Acetate membrane.

Key features:

  • Higher flux and better mechanical stability compared to standard cellulose acetate.
  • Increased chlorine resistance compared to polyamide thin-film elements.
  • NSF/ANSI/CAN 61 certified.
  • Application: Brackish water desalination and process stream concentration.

Product water

CE8040F Element Specification Testing conditions: 2,000 ppm NaCl solution at 420 psi (2,900 kPa) operating pressure, 77°F (25°C), pH 5.5 and 15% recovery. Average salt rejection after 24 hours of operation.

  • Average Permeate Flow: 7,000 gpd (26.5 m³/day)
    • Individual flow rate may vary with a minimum of 5,600 gpd (21.2 m³/day).
  • Average NaCl Rejection: 98.0 %
  • Minimum NaCl Rejection: 97.0%

Operating limits

  • Typical Operating Pressure: 140 – 400 psi (965-2,758 kPa)
  • Maximum Operating Pressure: 600 psi (4,137 kPa)
  • Typical Operating Flux: 10-18 GFD (17-30 LMH)
  • Maximum Temperature:
    • Continuous operation: 86°F (30°C)
    • Clean-In-Place (CIP): 86°F (30°C)
  • pH Range:
    • Continuous operation: 5.0-6.5
    • Clean-In-Place (CIP): 3.0-8.0
  • Maximum Pressure Drop:
    • Over an element: 15 psi (103 kPa)
    • Per housing: 50 psi (345 kPa)
  • Chlorine Tolerance: 0.5 ppm nominal, 1.0 ppm max

Feed water

  • NTU < 1
  • SDI₁₅ < 5

Mechanical / hydraulic

CE8040F Element Properties

  • Active Area: 350 ft² (32.5 m²)
  • Outer Wrap: Fiberglass
  • Feed Spacer: 34 mil
  • Part Number: 3097264

CE8040F Dimensions and Weight

  • Type: Female
  • Length (A): 40.0 inches (101.6 cm)
  • Diameter (B): 1.125 inches (2.86 cm)
  • Outer Diameter (C): 7.9 inches (20.1 cm)
  • Boxed Weight: 36 lbs. (16.3 kg)