GK2540F30

Engineering summary from PDF text extraction for GK2540F30. Verify every value with the OEM datasheet.

Summary

Product identification

The G-Series family of proprietary thin-film ultrafiltration (UF) membrane elements, specifically the GK Series, are characterized by a molecular weight cutoff (MWCO) of 3,500 on polyethylene glycol. These elements feature a smooth, fouling-resistant membrane surface.

GK Elements are designed for:

  • Surface water pretreatment
  • Color/Total Organic Carbon (TOC) reduction
  • Chemical purification

Operating limits

  • Typical Operating Flux: 5-20 GFD (8-34 LMH)
  • Maximum Operating Pressure: 400 psi (2,760 kPa)
  • Maximum Temperature:
    • Continuous Operation: 122°F (50°C)
    • Clean-In-Place (CIP): 122°F (50°C)
  • pH Range:
    • Continuous Operation: 2.0-10.0
    • Clean-In-Place (CIP): 1.0-13.0 (Refer to Cleaning Guidelines Technical Bulletin TB1194)
  • Maximum Pressure Drop:
    • Over an element: 15 psi (103 kPa)
    • Per housing: 60 psi (414 kPa)
  • Chlorine Tolerance: 20-50 ppm days

Mechanical / hydraulic

Element Specifications

  • Membrane: G-Series, Thin-Film Membrane (TFM)
  • MWCO: 3,500 Dalton
ModelAverage Permeate Flow gpd (m³/day) (1)Spacer mil (mm)Active Area ft² (m²)Outer WrapPart Number
GK2540F30420 (1.6)30 (0.76)28 (2.6)Fiberglass1207129
GK2540F50270 (1.0)50 (1.27)22 (2.0)Fiberglass1207130
GK4040C501,020 (3.9)50 (1.27)67 (6.2)Cage1207142
GK4040F301,600 (6.0)30 (0.76)85 (7.9)Fiberglass3050009
GK4040F501,000 (3.8)50 (1.27)66 (6.1)Fiberglass3050008
GK8040C504,100 (15.5)50 (1.27)300 (27.9)Cage1207151
GK8040F305,900 (22.3)30 (0.76)364 (33.8)Fiberglass1207152
GK8040F504,000 (15.1)50 (1.27)284 (26.4)Fiberglass1207153

(1) Flux specifications are based on fouling-free water at 85 psi (586 kPa) operating pressure, 77°F (25°C), and 10% recovery. Individual element flux may vary ± 25%.

Dimensions and Weight

ModelTypeDimensions, inches (cm) ABCWeight lbs (kg)
GK2540F**Male40.0 (101.6)0.752.4 (6.1)4 (1.8)
GK4040C**Female40 (101.6)0.625 (1.59)3.9 (9.9)9 (4.1)
GK4040F**Male40.0 (101.6)0.75 (1.90)3.9 (9.9)9 (4.1)
GK8040F**Female40.0 (101.6)1.125 (2.86)7.9 (20.1)29 (13.2)
GK8040C**Female40.0 (101.6)1.125 (2.86)7.9 (20.1)29 (13.2)

Note: A, B, C refer to dimensions detailed in diagrams not provided in this extract (Figure 1: Element Dimensions Diagram – Female, Figure 2: Element Dimensions Diagram – Male). See the official PDF for exact tabulated values and diagrams.


Disclaimer: This summary is based on the provided text extract and may miss figures, footnotes, or recent revisions. For contractual purposes, data must match the official OEM PDF revision used on the project.