AWC-UF-405

Engineering summary from PDF text extraction for AWC-UF-405. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: AWC® UF-405
  • Description: MF/UF Low pH Cleaning Compound

Advantages

  • Low pH membrane-cleaning compound for dissolution of carbonate and phosphate scales from microfiltration and ultrafiltration surfaces and pores
  • Effectively dissolves and chelates iron, aluminum and other metal oxides
  • Buffered to maintain pH range even when product is accidentally overdosed
  • Compatible with most UF/MF modules
  • Certified by NSF to NSF/ANSI Standard 60

Typical Properties

  • Appearance: White crystalline powder
  • Odor: Characteristic
  • Solubility in water: Soluble
  • pH (1% solution): 2 - 3

Chemical Feeding and Control

  • Use potable water free of residual chlorine or other oxidizing agents (RO permeate or DI water preferred).
  • Prepare cleaning solution by adding 10-20 lbs of AWC UF-405 for every 100 gallons of water (~1–2.5 wt% Solution), depending on severity of fouling.
  • Heat water to the maximum temperature allowed by the module manufacturer.
  • Circulate cleaning solution throughout modules with filtrate valve closed, in feed direction for 30 min (tubular designs).
  • Maintain a pH of 2-3 during circulation.
  • Reverse flow direction and circulate for 30 more minutes.
  • Measure pH every 15 minutes. Add AWC UF-405 as necessary to maintain pH 2-3.
  • Repeat process until solution pH remains stable for two consecutive readings.
  • Systems allowing back flushing may be back flushed with cleaning solution from filtrate to feed for 15 minutes.
  • Flush modules with MF/UF filtrate after cleaning.

Safety & Handling

  • Avoid breathing dust. Do not get in eyes, on skin or clothing.
  • Keep container closed.
  • Wash thoroughly after handling.
  • Refer to the Safety Data Sheet for more information.

Packaging

  • 50 lb. pails
  • 400 lb. non-returnable plastic drums

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.