Datasheet summary
P3-Ultrasil 110
Engineering summary from PDF text extraction for P3-Ultrasil 110. Verify every value with the OEM datasheet.
Summary
Product identification
P3-ultrasil® 110 is an alkaline, liquid detergent for membrane filtration plants.
Properties
Concentrate
- Appearance: clear, brown liquid
- Storage stability: 0 - 40 °C in original sealed container
- Solubility: at 20 °C miscible with water in any proportion
- Density: 1.05 - 1.29 g/cm³
- P content: 0.06 %
- N content: 0.50 %
- Flash point: not applicable
Application solution
- pH: 11.9 - 12.5 (1 %, 20 °C, 0 °d water)
- Conductivity: 4.0 mS/cm (1 %, 20 °C, deionized water)
Material compatibility
Metals
- Compatible with: austenitic CrNi steels (quality at least DIN 1.4301 = AISE 304)
- Discolorations may occur with: copper and brass
- Not intended for use with: aluminium
Membrane materials
- Compatible with: alkali-resistant membranes such as polysulphone, fully aromatic polyamide, polyacrylonitrile, polypropylene, α-aluminium oxide and zirkonium dioxide
- Limited resistance: Polypiperazine amide, polyvinyl difluoride and cellulose
- Not intended for use with: cellulose acetate membranes (may be damaged)
- Potential issue: Polyether urea and electrodialysis membranes may be irreversibly blocked by anionic surfactants.
Application
P3-ultrasil 110 is suitable for cleaning micro-, ultra-, nanofiltration, and reverse osmosis plants in the Dairy and Beverage Industries.
Mode of application
- Recommended concentrations: 1.5 to 3.0 %
- Recommended temperature: up to 85 °C
- Higher concentrations and temperatures may be permitted exceptionally.
- All treated surfaces should be rinsed residue-free with water after cleaning.
- Measurement of surface tension in the rinsing water is recommended as additional control.
- Can be used in combination with P3-oxonia or P3-ultrasil 02.
- Manufacturers’ limitations regarding pH and temperature stability of membranes and modules should be adhered to.
Monitoring
Concentration determination
- Titration:
- Receiving flask: 50 ml application solution
- Titration solution: 0.5 n HCl
- Indicator: Phenolphthalein
- Titration factor: 0.58
- Formula: Volume added (ml) x 0.58 = % P3-ultrasil 110
- Conductivity:
- Specific conductivity of P3-ultrasil 110 at various concentrations is provided in a graph and measured values list.
- Dosage can be performed automatically conductivity-controlled.
Disclaimer
Extraction may miss figures, footnotes, or revisions; contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.