Back to Kurita
Kurita logo

Datasheet summary

Vitec® 1000

Engineering summary from PDF text extraction for Vitec® 1000. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Product Name: Vitec® 1000
  • Product Type: Liquid antiscalant
  • Manufacturer: Avista Technologies, Inc.

Operating Limits

  • NSF/ANSI 60 Certified: Yes, for use in systems producing drinking water.

Feed Water Application

  • Intended Use: Inhibits scale in feedwaters with low potential for colloidal and silt fouling (e.g., groundwater applications).
  • Compatibility: Compatible with all reverse osmosis (RO) membranes, including polyamide and cellulose acetate types from all major manufacturers.

Product Water

  • Certified for Drinking Water: Yes, under NSF/ANSI 60.

Chemical Properties

  • Active Ingredient: 35% by weight polyacrylic acid.
  • Molecular Weight: 2000 (tight range).
  • pH (10% solution): 3.0 - 5.0
  • Specific Gravity (@ 20°C): 1.15 - 1.25
  • Appearance: Clear liquid

Performance Benefits

  • Scale Inhibition: Powerful against Calcium Carbonate (CaCO₃), Calcium Sulfate (CaSO₄), Barium Sulfate (BaSO₄), Strontium Sulfate (SrSO₄), and Calcium Fluoride (CaF₂).

Instructions for Use

  • Injection Point: Downstream of multimedia filters and upstream of cartridge filters.
  • Typical Dose: 2-5 mg/l. A site-specific dose can be determined using Avista Advisor software.
  • Dilution:
    • Formulated for neat injection.
    • If dilution is required, use deionized water, RO permeate, or softened water.
    • Minimum solution strength should not be less than 10% to maintain the internal bacteriostat.

Packaging and Storage

  • Available Pack Sizes:
    • Pail: 45 lb
    • Drum: 525 lb
    • IBC tote: 2500 lb
  • Storage: Protect from freezing.