Vitec® 3000

Engineering summary from PDF text extraction for Vitec® 3000. Verify every value with the OEM datasheet.

Summary

Product identification

Vitec® 3000 is a liquid antiscalant and dispersant compatible with organic coagulants. It is designed for reverse osmosis (RO) and nanofiltration (NF) membrane systems.

Applications include:

  • Preventing scale precipitation and dispersing colloidal particles in cellulose acetate and polyamide membrane systems.
  • Use in seawater and brackish water for potable and industrial water production.
  • Approved for use in systems producing drinking water in the UK (conforming to DIN 15040) and by NSF International under NSF/ANSI Standard 60.

Operating limits

Feed water

  • Effective in a wide variety of feedwaters and pH ranges.
  • Effective against scale including Calcium Carbonate (CaCO₃), Calcium Sulfate (CaSO₄), Barium Sulfate (BaSO₄), Strontium Sulfate (SrSO₄), Calcium Fluoride (CaF₂), and Silica (SiO₂).
  • Features crystal modification to distort inorganic salt crystal growth and reduce fouling.

Instructions for Use

Injection

  • Inject downstream of multimedia filters and upstream of cartridge filters for best results.

Dosing

  • Typical dose ranges from 2-5 mg/l.
  • Site-specific doses can be determined using the Avista Advisor software program.

Dilution

  • Formulated for neat injection.
  • If dilution is required, use deionized (DI) water or RO permeate. Softened water may be used if DI or RO permeate is unavailable.
  • Dilution should not result in a solution strength of less than 1%.
  • DI-quality water must be used for dilutions below 10%. This protects the internal bacteriostat.

Product Information

Specifications

  • Appearance: Clear, amber liquid
  • pH (as supplied): 10.7-11.8
  • Specific gravity (@25°C): 1.2-1.3

Packaging

FormatAmericas/AsiaEMEA
Pail45 lb23 kg
Drum500 lb230 kg
IBC tote2500 lb1100 kg
  • Drumless or bulk tanker delivery is available on request.