Autotrol 255 / 460
Engineering summary from PDF text extraction for Autotrol 255 / 460. Verify every value with the OEM datasheet.
Summary
Product identification
- Product Line: Autotrol Control Valves
- Model: Autotrol 255 Control Valve - 460 Series
Technical Specifications
Valve Body & Components
- Valve Body Material: Glass-filled thermoplastic – NSF Listed material
- Rubber Components: Compounded for cold water – NSF Listed material
- Valve Materials Certification: WQA Gold Seal Certified to ORD 0902, NSF/ANSI 44, CE, ACS
- Weight (Valve with Control): 1.8 kg (4 lbs)
Operating Limits
- Recommended Operating Pressure: 1.38 - 8.27 bar (20 - 120 psi)
- Hydrostatic Test Pressure: 20.69 bar (300 psi)
- Water Temperature: 2-38°C (35-100°F)
- Ambient Temperature: 2-48.9°C (35-120°F) (Recommend use of outdoor cover for direct sunlight applications)
Controller Electrical
- Controller Operating Voltage: 12 VAC (Requires use of Pentair supplied transformer)
- Input Supply Frequency: 50 or 60 Hz (Controller configuration dependent)
- Motor Input Voltage: 12 VAC
- Controller System Power Consumption: 3 W average
Transformer Specifications
- Output Voltage: 12 VAC 150 mA
- Input Options: 230 VAC 50/60 Hz
- Plug Options: United Kingdom Plug, Mainland Europe Plug
- Requirement: All Controllers require the use of a Pentair supplied transformer.
Valve Connections
- Tank Thread: 2-½ inches – 8, male
- Brine Line: ¼ or ⅜ inch NPT, male; air check built into valve
- Inlet/Outlet Manifold: 1 inch NPT or BSPT, female; or ¾ inch NPT or BSPT, male; or ½ inch NPT or BSPT, male (thermoplastic)
- Distributor Tube (diameter): 27 mm (1.050 inch) or 20.6 mm (13⁄₁₆ inch)
- Drain Line: ½ inch (manifold dependent)
- Distributor Tube (length): 29 mm ± 3 mm (1-⅛ ± ⅛ inch) above top of tank
Performance
Flow Rate (Valve Only)
- Service @ 1.03 bar (15 psi) drop: 3.52 m³/h (15.5 gpm)
- Backwash @ 1.72 bar (25 psi) drop: 1.36 m³/h (6.0 gpm)
- Service Kv: 3.4 (Cv = 3.99)
- Backwash Kv: 1.0 (Cv = 1.20)
Brine Refill
- Fixed Rate: 0.33 gpm (1.25 Lpm)
- Optional Fixed Rate (small tanks): 0.14 gpm (0.53 Lpm)
Backwash Flow Control
- Sizing: Backwash flow controls sized for 5.0 gpm/ sq. ft.
Controller Features
460 Time Clock Characteristics
- Simple, precise electronic time clock (chronometric)
- 1- or 30-days regeneration setting
- 12 V operation
460i Volumetric Characteristics
- Same features as the 460 Time Clock, plus:
- Capacity setting
- Calendar override
- 7 days variable reserve
- 12 V operation
- Standard manifold, 1 inch turbine