Back to Autotrol Control Valves
Autotrol logo

Datasheet summary

Autotrol Performa Cv Logix

Engineering summary from PDF text extraction for Autotrol Performa Cv Logix. Verify every value with the OEM datasheet.

Summary

Product identification

  • Series: Performa CV Control Valve - Logix Series
  • Brand: Autotrol

Logix Series Controllers

742 Time Clock Controller

  • Electronic time clock (chronometric)
  • 1- or 99-day regeneration setting (days interval) or days of the week
  • 12 V operation
  • Filter or conditioner setting in one control
  • Fully programmable cycle times
  • Salt setting in 10-gram increments
  • Compatible with: 255, 263, 268, 273, 278, and Magnum IT control valves

762 Demand Controller

  • Simple, economic electronic demand (volumetric)
  • Calendar override
  • 12 V operation
  • 28-day variable reserve
  • Automatic capacity calculations
  • Fully programmable cycle times
  • Salt setting in 10-gram increments
  • Compatible with: 255, 263, 268, 273, 278, and Magnum IT control valves

764 Demand Controller

  • Same features as the 762, plus:
    • Multi-tank applications (twin alternating, multi-tank parallel)
    • Control lockout
    • Remote regeneration

Transformer - All Controllers

  • Requires a Pentair-supplied transformer.
  • Output Voltage: 12 VAC 150 mA
  • Input Options: 230 VAC 50/60 Hz
  • Plug Options: United Kingdom Plug, Mainland Europe Plug

Valve Specifications

  • Body Material: Glass-filled thermoplastic – NSF Listed
  • Rubber Components: Compounded for cold water – NSF Listed
  • Certifications: WQA Gold Seal Certified to ORD 0902, NSF/ANSI 44, CE, ACS
  • Weight (Valve with Control): 2.42 kg (5.34 lbs)
  • Controller Operating Voltage: 12 VAC (Requires Pentair-supplied transformer)
  • Controller System Power Consumption: 3 W average
  • Input Supply Frequency: 50 or 60 Hz (Controller configuration dependent)

Operating Limits

  • Recommended Operating Pressure: 1.38-8.27 bar (20-120 psi)
  • Hydrostatic Test Pressure: 20.69 bar (300 psi)
  • Water Temperature: 2-38°C (35-100°F)
  • Ambient Temperature: 2-48.9°C (35-120°F) (Recommend use of outdoor cover for direct sunlight applications)

Flow Rates (Valve Only)

  • Service @ 1.03 bar (15 psi) drop: 5.7 m³/h (25.0 gpm)
  • Backwash @ 1.72 bar (25 psi) drop: 4.5 m³/h (20.0 gpm)
  • Service Kv: 5.6 (Cv = 6.50)
  • Backwash Kv: 3.5 (Cv = 4.00)

Valve Connections

  • Tank Thread: 2¹⁄₂ inches – 8, male
  • Inlet/Outlet Threads: 1³⁄₄ inches – 12 UNC-2A male
  • Drain Line: ³⁄₄ inch NPT, male
  • Brine Line: ³⁄⁸ inch NPT, male
  • Distributor Tube Diameter: 27 mm (1.050 inch)
  • Distributor Tube Length: 13 ± 13 mm (¹⁄₂ ± ¹⁄₂-inch) above top of tank

Dimensions

See the official PDF for exact tabulated dimensions (A-I in cm and inches).

Performance

Flow Rate vs Pressure Drop

See the official PDF for a graph illustrating flow rate versus pressure drop for both service and backwash cycles.

Backwash Flow Control

See the official PDF for a table of backwash flow rates in gpm and Lpm for controls numbered 7 through 14.

Injector Performance

  • New injectors for high-efficiency regeneration are standard with Logix Controllers.
  • Actual injector performance is dependent on resin used, tank geometry, elevated drain, etc. Data was taken using an empty tank.
  • See the official PDF for detailed injector performance charts (Injectors "H" through "L" and "Q", "N", "R") which include psi, bar, m³/hr, gallons per minute, and total brine draw/rinse for different tank sizes (9-inch through 21-inch).

Options

  • Turbine for Demand Units: Internal Standard Autotrol 25 mm (1-inch) turbine
  • Bypass Valve, Model 1265: Thermoplastic, 1-inch flow path
  • Bypass Fitting Kits:
    • Copper, Sweat Tube Adapter (32, 25 or 19 mm)
    • CPVC, Solvent Weld Tube Adapter (25 or 19 mm)
    • Plastic NPT or BSPT Pipe Adapter (25 or 19 mm male)
    • Stainless steel NPT or BSPT Pipe Adapter (25 or 19 mm male)
  • Brine Refill Controls:
    • 0.33 gpm (1.25 Lpm) fixed
    • 0.74 gpm (2.8 Lpm) fixed
    • 1.3 gpm (4.92 Lpm) fixed

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.