Datasheet summary
Autotrol Performa Cv Logix
Engineering summary from PDF text extraction for Autotrol Performa Cv Logix. Verify every value with the OEM datasheet.
Summary
Product identification
- Series: Performa CV Control Valve - Logix Series
- Brand: Autotrol
Logix Series Controllers
742 Time Clock Controller
- Electronic time clock (chronometric)
- 1- or 99-day regeneration setting (days interval) or days of the week
- 12 V operation
- Filter or conditioner setting in one control
- Fully programmable cycle times
- Salt setting in 10-gram increments
- Compatible with: 255, 263, 268, 273, 278, and Magnum IT control valves
762 Demand Controller
- Simple, economic electronic demand (volumetric)
- Calendar override
- 12 V operation
- 28-day variable reserve
- Automatic capacity calculations
- Fully programmable cycle times
- Salt setting in 10-gram increments
- Compatible with: 255, 263, 268, 273, 278, and Magnum IT control valves
764 Demand Controller
- Same features as the 762, plus:
- Multi-tank applications (twin alternating, multi-tank parallel)
- Control lockout
- Remote regeneration
Transformer - All Controllers
- Requires a Pentair-supplied transformer.
- Output Voltage: 12 VAC 150 mA
- Input Options: 230 VAC 50/60 Hz
- Plug Options: United Kingdom Plug, Mainland Europe Plug
Valve Specifications
- Body Material: Glass-filled thermoplastic – NSF Listed
- Rubber Components: Compounded for cold water – NSF Listed
- Certifications: WQA Gold Seal Certified to ORD 0902, NSF/ANSI 44, CE, ACS
- Weight (Valve with Control): 2.42 kg (5.34 lbs)
- Controller Operating Voltage: 12 VAC (Requires Pentair-supplied transformer)
- Controller System Power Consumption: 3 W average
- Input Supply Frequency: 50 or 60 Hz (Controller configuration dependent)
Operating Limits
- Recommended Operating Pressure: 1.38-8.27 bar (20-120 psi)
- Hydrostatic Test Pressure: 20.69 bar (300 psi)
- Water Temperature: 2-38°C (35-100°F)
- Ambient Temperature: 2-48.9°C (35-120°F) (Recommend use of outdoor cover for direct sunlight applications)
Flow Rates (Valve Only)
- Service @ 1.03 bar (15 psi) drop: 5.7 m³/h (25.0 gpm)
- Backwash @ 1.72 bar (25 psi) drop: 4.5 m³/h (20.0 gpm)
- Service Kv: 5.6 (Cv = 6.50)
- Backwash Kv: 3.5 (Cv = 4.00)
Valve Connections
- Tank Thread: 2¹⁄₂ inches – 8, male
- Inlet/Outlet Threads: 1³⁄₄ inches – 12 UNC-2A male
- Drain Line: ³⁄₄ inch NPT, male
- Brine Line: ³⁄⁸ inch NPT, male
- Distributor Tube Diameter: 27 mm (1.050 inch)
- Distributor Tube Length: 13 ± 13 mm (¹⁄₂ ± ¹⁄₂-inch) above top of tank
Dimensions
See the official PDF for exact tabulated dimensions (A-I in cm and inches).
Performance
Flow Rate vs Pressure Drop
See the official PDF for a graph illustrating flow rate versus pressure drop for both service and backwash cycles.
Backwash Flow Control
See the official PDF for a table of backwash flow rates in gpm and Lpm for controls numbered 7 through 14.
Injector Performance
- New injectors for high-efficiency regeneration are standard with Logix Controllers.
- Actual injector performance is dependent on resin used, tank geometry, elevated drain, etc. Data was taken using an empty tank.
- See the official PDF for detailed injector performance charts (Injectors "H" through "L" and "Q", "N", "R") which include psi, bar, m³/hr, gallons per minute, and total brine draw/rinse for different tank sizes (9-inch through 21-inch).
Options
- Turbine for Demand Units: Internal Standard Autotrol 25 mm (1-inch) turbine
- Bypass Valve, Model 1265: Thermoplastic, 1-inch flow path
- Bypass Fitting Kits:
- Copper, Sweat Tube Adapter (32, 25 or 19 mm)
- CPVC, Solvent Weld Tube Adapter (25 or 19 mm)
- Plastic NPT or BSPT Pipe Adapter (25 or 19 mm male)
- Stainless steel NPT or BSPT Pipe Adapter (25 or 19 mm male)
- Brine Refill Controls:
- 0.33 gpm (1.25 Lpm) fixed
- 0.74 gpm (2.8 Lpm) fixed
- 1.3 gpm (4.92 Lpm) fixed