Summary
Product Identification
- Product Line: Clack Control Valves
- Model: WS1 (Water Specialist 1”)
- Certification: NSF/ANSI 44, 61 and 372
Operating Limits
- Operating Pressures: 20 psi – 125 psi
- Operating Temperatures: 40º – 110º F
Feed Water
- Compatible Regenerants/Chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines.
Product Water (Meter Specifications)
- Accuracy: ± 5%
- Flow Rate Range: 0.25 – 27 gpm
- Gallon Range: 20 – 50,000 gallons
- Totalizer: 1000 - 9,999,000 gallons
Electrical Specifications
- AC Adapter:
- Supply Voltage: 120V AC (US) / 230V AC (International)
- Supply Frequency: 60 Hz (US) / 50 Hz (International)
- Output Voltage: 12V AC
- Output Current: 500 mA
Mechanical / Hydraulic
- Inlet/Outlet Fittings: ¾" to 1.5” NPS
- Valve Material: Noryl (1) or equivalent
- Service Flow Rate @ 15 psi drop: 27 gpm
- Backwash Flow Rate @ 25 psi drop: 27 gpm
- Cv Service: 7.0
- Cv Backwash: 5.4
- Distributor Pilot: 1.050" OD Pipe (¾" NPS)
- Drain Line: ¾” or 1” NPT
- Brine Line: 3/8” or ½” OD Poly Tube
- Mounting Base: 2 ½” - 8 NPSM
- Height From Top Of Tank: 7 3/8”
- Weight: 4.5 lbs.
Valve Features
- Solid state microprocessor with easy access front panel settings
- Three modes of operation; meter immediate, meter delayed, or time clock delayed
- Double backwash feature
- Capable of 36 pre-programmed regeneration cycles
- Days override feature; 1 – 28 days available
- Backwash and brining ability to 21” diameter tanks
- Downflow/upflow regeneration
- Nonvolatile memory for system configuration and data
- Coin Cell Lithium battery back-up with 8-hour carry over
- 12-volt output AC Adapter
- Pre or Post treated water regenerant refill
- Patented one piece expanding seal spacer stack assembly (U.S. Patent 6,402,944)
- Patented linearly reciprocating piston operation (U.S. Patent 6,444,127)
- Reliable and proven DC drive
Tank Applications
- Water Softener: 6” – 21” diameter tanks
- Water Filter: 6” – 21” diameter tanks
Cycles of Operation (Softener Downflow)
| Cycle | Range of times (minutes) |
|---|---|
| 1. Backwash 1st (upflow) | 6 - 12 |
| 2. Regenerate Draw/Slow Rinse (downflow) | 45 - 75 |
| 3. Backwash 2nd (upflow) | 3 - 12 |
| 4. Fast Rinse (downflow) | 3 - 8 |
| 5. Regenerant Refill | As Programmed |
| 6. Service (downflow) |