Summary

Product identification

  • Product Line: Clack Control Valves
  • Model: WS1TC Water Specialist Control Valve
  • Certifications: NSF/ANSI 44, 61 and 372

Operating limits

  • Operating Pressures: Minimum 20 psi – Maximum 125 psi
  • Operating Temperatures: Minimum 40º F – Maximum 110º F

Feed water

  • Compatible regenerants/chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines.

Product water

  • Post treated water regenerant refill

Electrical

  • AC Adapter:
    • U.S. Specification:
      • Supply Voltage: 120V AC
      • Supply Frequency: 60 Hz
      • Output Voltage: 12V AC
      • Output Current: 500 mA
    • International Specification:
      • Supply Voltage: 230V AC
      • Supply Frequency: 50 Hz
      • Output Voltage: 12V AC
      • Output Current: 500 mA
  • Battery Backup: Coin Cell Lithium battery with 8-hour carry over.
  • Line Frequency Detection: Auto detection of 50/60 Hz.

Mechanical / hydraulic

  • Inlet/Outlet Fittings: ¾" to 1.5” NPS
  • Service Flow Rate: 27 gpm @ 15 psi drop (includes bypass)
  • Backwash Flow Rate: 27 gpm @ 25 psi drop (includes bypass)
  • Cv Service: 7.0
  • Cv Backwash: 5.4
  • Valve Material: Noryl or equivalent
  • Regeneration Type: Downflow
  • Tank Diameter Compatibility: 6” – 21” diameter for water softeners and water filters.
  • Distributor Pilot Pipe Size: 1.050” OD Pipe (¾" NPS)
  • Drain Line Connection: ¾” or 1” NPT
  • Brine Line Connection: 3/8” or ½” OD Poly Tube
  • Mounting Base Thread: 2 ½” - 8 NPSM
  • Height from Top of Tank: 7 3/8”
  • Weight: 4.5 lbs.

Features

  • More informative 4 digit LCD Display with Status Indicators
  • Solid state microprocessor with easy access front panel settings
  • Front panel display for time of day, days until next regeneration
  • Days between regeneration feature: 1–99 days standard; 7-day optional
  • Double backwash feature
  • 10 selectable pre-programmed regeneration cycles
  • Auto detection of 50/60 Hz line frequency, with automatic 12/24 hour time keeping formats
  • Patented one piece expanding seal spacer stack assembly (U.S. Patent 6,402,944)
  • Patented linearly reciprocating piston operation (U.S. Patent 6,444,127)
  • Reliable and proven DC drive

Cycles of Operation (Softener Downflow)

  • Cycle 1: Backwash 1st (upflow) - 3 to 12 minutes
  • Cycle 2: Regenerate Draw/Slow Rinse (downflow) - 50 to 70 minutes
  • Cycle 3: Backwash 2nd (upflow) - 3 to 12 minutes
  • Cycle 4: Fast Rinse (downflow) - 3 to 8 minutes
  • Cycle 5: Regenerant Refill (in service with treated water) - As Programmed
  • Cycle 6: Service (downflow)