Back to Clack Control Valves
Clack logo

Datasheet summary

Clack 2620 WS1.25EI

Engineering summary from PDF text extraction for Clack 2620 WS1.25EI. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Line: Clack Control Valves
  • Model: WS1.25EI (Water Specialist 1.25” EI Control)
  • Certifications: NSF/ANSI 44, 61 and 372.
  • Patents: U.S. Patents 6,402,944 and 6,444,127

Features

  • Solid state microprocessor with front panel settings.
  • Front panel display: time of day, days until next regeneration, volume remaining, current flow rate, and total volume used (Totalizer).
  • Regeneration initiation methods: meter immediate, meter delayed, time clock delayed, or pressure differential.
  • Optional double backwash feature.
  • Fully adjustable 6-cycle control: backwash, downflow brining/slow rinse, second backwash, fast rinse, refill, and downflow service.
  • Coin cell lithium battery back-up with 8-hour carry-over.
  • Backwash and brining ability for up to 21” diameter tanks.
  • Downflow or upflow brining regeneration.
  • 12-volt output AC adapter.
  • Patented one-piece expanding seal spacer stack assembly.
  • Patented linearly reciprocating piston operation.
  • Control valve design for optimum service and backwash rates.
  • Post-treated water regenerant refill.
  • 24-hour clock.
  • Mixing valve option available.
  • DC drive.
  • Options: Backwash Filter, Weather Cover.

Operating limits

  • Operating Pressures: 20 - 125 psi (1.4 - 8.6 bar)
  • Operating Temperatures: 40º - 110º F (4º - 43ºC)

Feed water

  • Compatible regenerants/chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines.

Product water

  • Cycles of Operation (Softener):
      1. Backwash 1st (upflow): 1-95 minutes
      1. Regenerate Draw/Slow Rinse (downflow): 1-180 minutes
      1. Backwash 2nd (upflow): 1-95 minutes
      1. Fast Rinse (downflow): 1-95 minutes
      1. Regenerant Refill (in service with treated water): 0.1-99.0 minutes
      1. Service (downflow)
  • Cycles of Operation (Filter):
      1. Backwash: 1-95 minutes
      1. Rinse: 1-95 minutes
      1. Regenerant Refill (in service with treated water): 0.1-99.0 minutes
      1. Service

Flow rates

  • Service: 129 lpm (7.7 m³/h) (34 gpm) @ 15 psi / 1 bar drop (includes meter).
  • Backwash: 121 lpm (7.3 m³/h) (32 gpm) @ 25 psi / 1.7 bar drop (acquired by use of external drain line flow control).
    • Tank size calculation @ 10 gpm of backwash per square foot of bed area / 407 lpm per m² of bed area.

Meter specifications

  • Accuracy: ± 5%
  • Flow Rate Range: 0.95 - 129 lpm
  • Volume Range: 0.02 - 5,700 m³
  • Totalizer: 0.001 - 9,999,000 m³

Electrical specifications

  • AC Adapter:
    • Supply Voltage: 120V AC (US) / 230V AC (International)
    • Supply Frequency: 60 Hz (US) / 50 Hz (International)
    • Output Voltage: 12V AC
    • Output Current: 500 mA

Mechanical / hydraulic

  • Inlet/Outlet Fittings: ¾" to 1.5” NPS
  • Cycles: Up to 6
  • Valve Material: Noryl® or equivalent
  • Regeneration: Downflow
  • Distributor Pilot: 1.32" OD Pipe (1" NPS) or 32mm OD
  • Drain Line: ¾” or 1” NPT
  • Brine Line: 3/8” or ½” OD Poly Tube
  • Mounting Base: 2 ½” - 8 NPSM
  • Height From Top Of Tank: 7 3/8” (187 mm)
  • Weight: 4.5 lbs. (2 kg)

Tank applications

  • Water Softener: 6” - 21” Diameter
  • Water Filter: 6” - 24” Diameter

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror