Datasheet summary
Clack 2666 WS1.25CI
Engineering summary from PDF text extraction for Clack 2666 WS1.25CI. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product Line: Clack Control Valves
- Model: WS1.25CI Water Specialist Control Valve
- Certifications: NSF/ANSI 44, 61 and 372
Operating Limits
- Operating Pressures: 20 - 125 psi (1.4 - 8.6 bar)
- Operating Temperatures: 40º - 110º F (4º – 43º C)
Feed Water
- Compatible Regenerants/Chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines.
Product Water
- Service Flow Rate (15 psi/1 bar drop): 129 lpm (7.7 m³/h) (34 gpm)
- Backwash Flow Rate (25 psi/1.7 bar drop): 121 lpm (7.3 m³/h) (32 gpm)
Meter Specifications
- Accuracy: ± 5%
- Flow Rate Range: 0.95 - 129 lpm
- Volume Range: 0.02 - 5,700 m³
- Totalizer: 1 m³ - 99,999 m³
Electrical Specifications
- AC Adapter:
- U.S. Supply Voltage: 120V AC
- International Supply Voltage: 230V AC
- Supply Frequency: 60 Hz (U.S.), 50 Hz (International)
- Output Voltage: 12V AC
- Output Current: 500 mA
Mechanical / Hydraulic
- Inlet/Outlet Fittings: ¾" to 1.5” NPS
- Valve Material: Noryl (1) or equivalent
- Regeneration Type: Downflow
- Tank Size Compatibility:
- Water Softener: 6" - 21" Diameter
- Water Filter: 6" - 24" Diameter
- Control Valve Height From Top Of Tank: 7 3/8" (187 mm)
- Weight: 4.5 lbs (2 kg)
- Distributor Pilot: 1.32" OD Pipe (1" NPS) or 32 mm OD
- Drain Line Fitting: ¾" or 1" NPT
- Brine Line Fitting: 3/8" or ½" OD Poly Tube
- Mounting Base: 2 ½" - 8 NPSM
Control Features
- Solid state microprocessor with front panel settings.
- Regeneration Initiation Methods: Meter immediate, meter delayed, time clock delayed, or pressure differential.
- Programming Units: ppm, French degrees, German degrees, or cubic meters.
- Regeneration Cycles: Up to 9 programmable cycles.
- Cycle Times: Programmable.
- Days Override: 1 – 28 days available.
- Battery Back-up: Coin Cell Lithium battery with 24-hour carry-over.
- Brining/Backwash: Ability to support tanks up to 21" diameter.
- Regenerant Refill: Pre or Post treated water; mixing valve option available.
- Alarm: Low salt alarm.
- Clock: 24-hour clock.
- Patents: U.S. Patent 6,402,944; U.S. Patent 6,444,127.
Cycles of Operation (Example Ranges)
- Backwash: 1 - 120 minutes
- Rinse: 1 - 120 minutes
- Pause (service): 1 - 480 minutes
- Brine (co-current): 1 - 180 minutes
- Refill (softener): 0.05 - 95.00 Kg
- Refill (filter): 0.05 - 95.00 Liters