Summary

Product Identification

  • Product Line: Clack Control Valves
  • Model: 2678 WS2H (Water Specialist 2" H)
  • Certifications: NSF/ANSI 44, 61, and 372

Mechanical / Hydraulic

  • Valve Type: 2" top mount or side mount control valve
  • Valve Body Material: Epoxy coated lead-free brass
  • Inlet/Outlet Connections: 2” Female NPT or BSPT / 2.5” Groove Lock
  • Drain Line Connection: 2” Female NPT/BSPT/2.5” Groove Lock
  • Brine Line Adapters: 1” Male NPT elbow and ¾” x 1” solvent weld elbow included; ½” or 5⁄8" OD Poly Tube Compression optional adapters.
  • Mounting Base: 4" - 8 UN, 6” Flange or Side Mount

Operating Limits

  • Service Flow Rate: 125 gpm (473 lpm) (28.4 m³/h) @ 15 psi / 1 bar drop (includes meter)
  • Backwash Flow Rate: 125 gpm (473 lpm) (28.4 m³/h) @ 25 psi / 1.7 bar drop
  • Cv Service: 32.3
  • Cv Backwash: 25.0
  • Operating Pressure (Min/Max): 20 - 125 psi (1.4 - 8.6 bar)
  • Operating Temperature (Min/Max): 40º - 110º F (4º - 43º C)

Feed Water Compatibility

  • Compatible Regenerants/Chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine, and chloramines.

Meter Specifications

  • Accuracy: ± 5%
  • Flow Rate Range: 1.5 - 125 gpm (5.7 - 473 lpm)
  • Volume Range: 10 - 999,000 gallons (38 - 3,796.2 liters x1000)
  • Totalizer Range: 1,000 - 999,999,000 gallons (3,786 - 3,785,407.9 liters x1000)

Cycles of Operation

  • Regeneration Type: Downflow
  • Maximum Cycles: Up to 9
  • Programmable Cycles: Fully programmable regeneration cycle sequences and times.
  • Regeneration Initiation Methods: Meter delayed, meter immediate, time clock delayed, or pressure differential.
  • Regenerant Refill: Pre or Post treated water.
  • Days Override: 1-28 days available.
  • Individual Cycle Ranges:
    • Backwash: 1 - 95 minutes
    • Brine (draw): 1 - 180 minutes
    • Slow Rinse: 1 - 95 minutes
    • Fast Rinse: 1 - 95 minutes
    • Refill: 0.1 - 99 minutes
    • Hold (service): 1 - 480 minutes

Tank Applications

  • Water Softener: 18” - 63" Diameter tanks
  • Water Filter: 18” - 48" Diameter tanks

Electrical Specifications

  • AC Adapter:
    • Supply Voltage: 120V AC (US) / 230V AC (International)
    • Supply Frequency: 60 Hz (US) / 50 Hz (International)
    • Output Voltage: 20V AC
    • Output Current: 750 mA

Dimensions & Weight

  • Valve Bodies (2" Female NPT/BSPT): 2.375” OD (2" NPS) / 63mm OD
  • Height (from top of tank, with QC Base):
    • 4" - 8 UN QC Base: 11.5” (292mm)
    • 6" Flange QC Base: 11.6” (294.6mm)
  • Shipping Weight (with internal meter): 50 lbs (22.7 Kg)