Back to Clack Control Valves
Clack logo

Datasheet summary

Clack 2867 WS1.25EE

Engineering summary from PDF text extraction for Clack 2867 WS1.25EE. Verify every value with the OEM datasheet.

Summary

Product Identification

Model: WS1.25EE Water Specialist Control Valve

Certifications: NSF/ANSI 44, 61, and 372

Operating Limits

  • Operating Pressures: 20 psi – 125 psi
  • Operating Temperatures: 40º – 110º F

Flow Rates

  • Service Flow Rate: 34 gpm (at 15 psi drop)
  • Backwash Flow Rate: 32 gpm (at 25 psi drop)
  • Cv Service: 8.8
  • Cv Backwash: 6.4

Meter Specifications

  • Accuracy: ± 5%
  • Flow Rate Range: 0.25 – 34 gpm
  • Gallon Range: 20 – 1,500,000 gallons
  • Totalizer: 1000 - 9,999,000 gallons

Mechanical / Hydraulic

  • Inlet/Outlet Fittings: ¾" to 1.5” NPS
  • Valve Material: Noryl (1) or equivalent
  • Regeneration Type: Downflow or upflow brining
  • Distributor Pilot: 1.32" OD Pipe (1" NPS) or 32mm OD
  • Drain Line: ¾” or 1” Male NPT
  • Brine Line: 3/8” or ½” OD Poly Tube Compression
  • Mounting Base: 2 ½” - 8 NPSM
  • Height from Top of Tank: 7 3/8”
  • Weight: 4.5 lbs.
  • Tank Compatibility: 6” – 21” diameter for Water Softener; 6” – 24” diameter for Water Filter.
  • Backwash and Brining Ability: Up to 21” diameter tanks

Electrical Specifications

  • AC Adapter:
    • US: 120V AC, 60 Hz supply; 12V AC, 500 mA output
    • International: 230V AC, 50 Hz supply; 12V AC, 500 mA output
  • Power: 12-volt output AC Adapter

Features

  • Solid state microprocessor with front panel settings
  • Front panel display shows time of day, days until regeneration, volume remaining, current flow, and total volume used.
  • Four regeneration initiation methods: meter immediate, meter delayed, time clock delayed, or pressure differential.
  • Optional double backwash feature.
  • Fully adjustable 6-cycle control: backwash, downflow brining slow rinse, second backwash, fast rinse, refill, and downflow service.
  • Coin cell lithium battery backup with 8-hour carry over.
  • Patented one piece expanding seal spacer stack assembly (U.S. Patent 6,402,944).
  • Patented linearly reciprocating piston operation (U.S. Patent 6,444,127).
  • Post treated water regenerant refill.
  • DC drive.

Cycles of Operation

  • Number of Cycles: Up to 6
  • Softener Cycle Time Ranges (minutes):
    • Backwash 1st (upflow): 1-95
    • Regenerate Draw/Slow Rinse (downflow): 1-180
    • Backwash 2nd (upflow): 1-95
    • Fast Rinse (downflow): 1-95
    • Regenerant Refill (in service with treated water): 0.1-99.0 or off
    • Service (downflow): Not specified
  • Filter Cycle Time Ranges (minutes):
    • Backwash: 1-95
    • Rinse: 1-95
    • Regenerant Refill: 0.1-99.0 or off

Compatible Chemicals

  • Sodium chloride
  • Potassium chloride
  • Potassium permanganate
  • Sodium bisulfite
  • Chlorine
  • Chloramines

Disclaimer: This extracted summary may omit figures, footnotes, or revisions. Contractual data must be verified against the official OEM PDF revision used for the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.