Back to Clack Control Valves
Clack logo

Datasheet summary

Clack 2869 WS3

Engineering summary from PDF text extraction for Clack 2869 WS3. Verify every value with the OEM datasheet.

Summary

Product Identification

  • Model: WS3 Water Specialist Control Valve
  • Certifications: NSF/ANSI 61 and 372

Operating Limits

  • Operating Pressures: 20 - 125 psi (1.4 - 8.6 bar)
  • Operating Temperatures: 40º - 110º F (4º - 43º C)

Feed Water / Chemical Compatibility

  • Compatible Regenerants/Chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine, and chloramines.

Hydraulic Performance

Control Valve Flow Rates

  • Service Flow Rate: 250 gpm (946 lpm) (56.8 m³/h) @ 15 psi / 1 bar drop
  • Backwash Flow Rate: 220 gpm (833 lpm) (50.0 m³/h) @ 25 psi / 1.7 bar drop
  • Cv Service: 64.6
  • Cv Backwash: 44.0

Meter Specifications (Optional)

  • Accuracy: ± 5%
  • Flow Rate Range: 3.5 - 350 gpm (13.3 - 1325 lpm)
  • Volume Range: 10 - 999,000 gallons (38 - 3,796.2 liters x1000)
  • Totalizer: 1,000 - 999,999,000 gallons (3,786 - 3,785,407.9 liters x1000)

Electrical Specifications

AC Adapter

  • Supply Voltage: 120V AC (US) / 230V AC (International)
  • Supply Frequency: 60 Hz (US) / 50 Hz (International)
  • Output Voltage: 20V AC
  • Output Current: 750 mA

Mechanical / Hydraulic

  • Valve Body Material: Epoxy coated lead free brass
  • Inlet/Outlet Connections: 3” Female NPT or BSPT
  • Drain Line Connection: 3” Female NPT/BSPT "No Groove Lock"
  • Brine Line Adapters: 1” Male NPT elbow and ¾” x 1” solvent weld elbow included
  • Mounting Base: 6” Flange or Side Mount Adapter
  • Height (from top of tank with 6" Flange QC Base): 12.5” (318mm)
  • Shipping Weight (without optional meter): 57 lbs (25.9 Kg)

Control Features

  • Regeneration Initiation Methods: Meter delayed, meter immediate, time clock delayed, pressure differential
  • Programmable Cycles: Up to 9 regeneration cycles
  • Regeneration Cycle Times (Programmable):
    • Backwash: 1 - 95 minutes
    • Brine (draw): 1 - 180 minutes
    • Slow Rinse: 1 - 95 minutes
    • Fast Rinse: 1 - 95 minutes
    • Refill: 0.1 - 99 minutes
    • Hold (service): 1 - 480 minutes
  • Regenerant Refill: Pre or Post treated water
  • Days Override: 1-28 days available
  • Back-up Power: Capacitor with up to 24-hour carry-over
  • Operation: Solid state microprocessor, DC drive, patented linearly reciprocating piston operation.

Tank Applications

  • Water Softener Tanks: 18” - 63” Diameter (standard injectors), up to 96” (with Brine Pump)