Datasheet summary

Clack 2985 WS1EI

Engineering summary from PDF text extraction for Clack 2985 WS1EI. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Line: Clack Control Valves
  • Model: WS1EI Twin Alternating Control Valve

Operating limits

  • Operating Pressures: 1.4 - 8.6 bar (20 psi – 125 psi)
  • Operating Temperatures: 4º - 43ºC (40º – 110º F)

Feed water

  • Compatible regenerants/chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines

Product water

  • Post fill and regeneration cycles: Treated/Soft water

Electrical

  • AC Adapter:
    • Supply Voltage: 230V AC
    • Supply Frequency: 50 Hz
    • Output Voltage: 12V AC
    • Output Current: 500 mA

Mechanical / hydraulic

  • Inlet/Outlet Fittings: ¾" to 1.5” NPS
  • Valve Material: Noryl (1) or equivalent
  • Regeneration: Downflow
  • Cycles: Up to 6
  • Flow Rates:
    • Service @15 psi/1 bar drop (includes bypass and meter): 106 lpm (6.36 m³/h) (28 gpm)
    • Backwash @ 25 psi/1.7 bar drop (includes bypass): 57 lpm (3.40 m³/h) (15 gpm)
    • Cv Service: 7.28
    • Cv Backwash: 2.96
  • Meter Specifications:
    • Accuracy: ± 5%
    • Flow Rate Range: 0.95 - 102 lpm
    • Gallon Range: 0.02 - 5,700 m³
    • Totalizer: 0.001 - 9,999,000 m³
  • Dimensions & Weight:
    • Distributor Pilot: 1.050" OD Pipe (¾" NPS)
    • Drain Line: ¾” or 1” Male NPT
    • Brine Line: 3/8” or ½” OD Poly Tube Compression
    • Mounting Base: 2 ½” - 8 NPSM
    • Height From Top Of Tank: 187 mm (7 3/8”)
    • Weight: 7.25 kg (16 lbs.)
  • Tank Applications:
    • Water Softener: 6” – 21” diameter
    • Water Filter: 6” – 16” diameter

Features

  • Solid state microprocessor with easy access front panel settings
  • Front panel display for time of day, days until next regeneration, volume remaining, current flow rate and total volume used (Totalizer), and Tank in Service Indication
  • Four methods to initiate regeneration: meter immediate, meter delayed, time clock delayed or pressure differential
  • Optional double backwash feature
  • Fully adjustable cycle times with 6-cycle control
  • Coin Cell Lithium battery back-up with 8 hour carry over
  • Backwash and brining ability to 21” diameter tanks
  • Downflow or upflow brining regeneration
  • 12-volt output AC Adapter
  • Patented one piece expanding seal spacer stack assembly U.S. Patent 6,402,944
  • Patented linearly reciprocating piston operation U.S. Patent 6,444,127
  • Reliable and proven DC drives

Cycles of Operation (Softener / Filter downflow)

  • Softener:
      1. Backwash 1st: 1-95 minutes or off
      1. Regenerate Draw/Slow Rinse: 1-180 minutes or off
      1. Backwash 2nd: 1-95 minutes or off
      1. Fast Rinse: 1-95 minutes or off
      1. Regenerant Refill: 0.1-99.0 minutes or off
      1. Service (downflow)
  • Filter:
    • Backwash: 1-95 minutes or off
    • Rinse: 1-95 minutes or off