Back to Pentair Control Valves
Pentair logo

Datasheet summary

Autotrol 255 / 460

Engineering summary from PDF text extraction for Autotrol 255 / 460. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product line: Autotrol 255 Control Valve - 460 Series
  • Type: Electronic time clock (chronometric)
  • Control features:
    • 1- or 30-day regeneration setting (Time Clock)
    • Capacity setting, calendar override, 7 days variable reserve (Volumetric)

Operating limits

  • Recommended Operating Pressure: 1.38 - 8.27 bar (20 - 120 psi)
  • Hydrostatic Test Pressure: 20.69 bar (300 psi)
  • Water Temperature: 2-38°C (35-100°F)
  • Ambient Temperature: 2-48.9°C (35-120°F) (Recommend use of outdoor cover for direct sunlight applications)

Electrical

  • Controller Operating Voltage: 12 VAC (Requires Pentair supplied transformer)
  • Input Supply Frequency: 50 or 60 Hz (Controller configuration dependent)
  • Motor Input Voltage: 12 VAC
  • Controller System Power Consumption: 3 W average
  • Transformer Output Voltage: 12 VAC 150 mA
  • Transformer Input Options: 230 VAC 50/60 Hz

Mechanical / hydraulic

  • Valve Body Material: Glass-filled thermoplastic – NSF Listed material
  • Rubber Components Material: Compounded for cold water – NSF Listed material
  • Valve Materials Certification: WQA Gold Seal Certified to ORD 0902, NSF/ANSI 44, CE, ACS
  • Weight (Valve with Control): 1.8 kg (4 lbs)
  • Tank Thread: 2-½ inches – 8, male
  • Brine Line: ¼ or ⅜ inch NPT, male; air check built into valve
  • Inlet/Outlet Manifold: 1 inch NPT or BSPT, female (brass or thermoplastic)
  • Distributor Tube Diameter: 27 mm (1.050 inch) or 20.6 mm (13⁄₁₆ inch)
  • Distributor Tube Length: 29 mm ± 3 mm (1-⅛ ± ⅛ inch) above top of tank
  • Drain Line: ½ inch (manifold dependent)

Flow Rate (Valve Only)

  • Service @ 1.03 bar (15 psi) drop: 3.52 m³/h (15.5 gpm)
  • Backwash @ 1.72 bar (25 psi) drop: 1.36 m³/h (6.0 gpm)
  • Service Kv: 3.4 (Cv = 3.99)
  • Backwash Kv: 1.0 (Cv = 1.20)

Bypass Inlet-Outlet Fitting Kits

  • Thermoplastic: 1-inch flow path, ½ inch NPT male, drain bypass
  • Copper, Sweat Tube Adapter: 25 or 19 mm (1 inch or ¾ inch)
  • CPVC, Solvent Weld Tube Adapter: 25 or 19 mm (1 inch or ¾ inch)
  • Plastic NPT or BSPT Pipe Adapter: 25 or 19 mm male (1 inch or ¾ inch)
  • Stainless steel NPT or BSPT Pipe Adapter: 25 or 19 mm male (1-inch or ¾ inch)

Brine Refill Controllers

  • Standard: 0.33 gpm (1.25 Lpm) fixed
  • Optional (small tanks): 0.14 gpm (0.53 Lpm) fixed