Datasheet summary
Autotrol 368
Engineering summary from PDF text extraction for Autotrol 368. Verify every value with the OEM datasheet.
Summary
Product Identification
AUTOTROL RESIDENTIAL VALVE 368
Technical Characteristics
- Easy, three-step programming: time-of-day, salt dosage, regeneration interval
- Full range of application settings: water saver and multiple slow-rinse cycles
- Battery-free memory retention: super capacitor provides time-of-day backup
- Water cycling design incorporates the time-tested reliability of Autotrol valve disc technology
- Multiple regeneration functions: quick cycle, delay (next 2 a.m.), instantaneous manual operation and increased regeneration frequency
- Large LED display with icon graphics for system functions (salt dosage, regeneration interval, camshaft position, and more)
- Fast, easy service with front-loading components
Technical Specifications
- Valve body: Glass-filled Noryl®
- Rubber components: Compounded for cold water
- Operating pressure: 1.38-8.61 bar
- Ambient temperature: 2-50°C (Recommended for indoor use only)
- Water temperature: 2-38°C
- Electrical rating: 12 V - 50 or 60 Hz
Valve Specifications
- Service flow rate (∆p = 1.3 bar drop): 3.77 m³/h
- Backwash flow rate (∆p = 1.72 bar drop): 0.62 m³/h
- Refill flow rate: 0.53 Lpm (0.14 gpm) - 1.25 Lpm (0.33 gpm)
- Flow rate (3.5 bar inlet - valve alone) accuracy range (± 5%): 1-57 Lpm
- Capacity range: 0.4-9.5 m³
- Regenerant Injectors: E, F, G, H and J
- DLFC (Drain Line Flow Control): 3.8 - 4.9 - 6.4 - 8.3 Lpm
- Bypass: METER OPTIONS (6 to 10-inch diameter tank)
Valve Connections
- Tank thread: 2½ inches - 8 male
- Inlet/outlet thread: ¾ inch BSPT, male
- Drain line: ½ inch BSPT, male
- Brine line: ⅜ inch BSPT, male
- Distributor tube diameter: 27 mm (1.050 inch)
- Distributor tube length: Flush to top of tank ± ½ inch
Tank Size Application
- Water softener tank size (recommended): 150-254 mm (6-10 inches)
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.