Back to Pentair Control Valves
Pentair logo

Datasheet summary

Autotrol Performa Cv Logix

Engineering summary from PDF text extraction for Autotrol Performa Cv Logix. Verify every value with the OEM datasheet.

Summary

Product Identification

AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES

Controllers

  • 742 TIME CLOCK: Electronic time clock (chronometric), 1- or 99-day regeneration setting, 12 V operation, filter or conditioner setting, programmable cycle times, salt setting in 10-gram increments.
  • 762 DEMAND: Simple, economic electronic demand (volumetric), calendar override, 12 V operation, 28-day variable reserve, automatic capacity calculations, programmable cycle times, salt setting in 10-gram increments.
  • 764 DEMAND: Same features as the 762, plus multi-tank applications (twin alternating, multi-tank parallel), control lockout, remote regeneration.

Transformer Specifications

  • Output Voltage: 12 VAC 150 mA
  • Input Options: 230 VAC 50/60 Hz
  • Plug Options: United Kingdom, Mainland Europe
  • All controllers require a Pentair-supplied transformer.

Valve Specifications

  • Valve Body: Glass-filled thermoplastic – NSF Listed material
  • Rubber Components: Compounded for cold water – NSF Listed material
  • Materials Certification: WQA Gold Seal Certified to ORD 0902, NSF/ANSI 44, CE, ACS
  • Weight (Valve with Control): 2.42 kg (5.34 lbs)

Operating Limits

  • Recommended Operating Pressure: 1.38-8.27 bar (20-120 psi)
  • Hydrostatic Test Pressure: 20.69 bar (300 psi)
  • Water Temperature: 2-38°C (35-100°F)
  • Ambient Temperature: 2-48.9°C (35-120°F) (Use of outdoor cover recommended for direct sunlight)

Electrical

  • Controller Operating Voltage: 12 VAC (Requires Pentair-supplied transformer)
  • Input Supply Frequency: 50 or 60 Hz (Controller configuration dependent)
  • Motor Input Voltage: 12 VAC
  • Controller System Power Consumption: 3 W average

Mechanical / Hydraulic

Valve Connections

  • Tank Thread: 2½ inches – 8, male
  • Inlet/Outlet Threads: 1¾ inches – 12 UNC-2A male
  • Drain Line: ¾ inch NPT, male
  • Brine Line: ⅜ inch NPT, male
  • Distributor Tube Diameter: 27 mm (1.050 inch)
  • Distributor Tube Length: 13 ± 13 mm (½ ± ½-inch) above top of tank

Flow Rates (Valve Only)

  • Service @ 1.03 bar (15 psi) drop: 5.7 m³/h (25.0 gpm)
  • Backwash @ 1.72 bar (25 psi) drop: 4.5 m³/h (20.0 gpm)
  • Service Kv: 5.6 (Cv = 6.50)
  • Backwash Kv: 3.5 (Cv = 4.00)

Performance

  • Backwash Flow Control: See the official PDF for exact tabulated values.

Dimensions

See the official PDF for exact tabulated values.

Options

  • Turbine for Demand Units: Internal Standard Autotrol 25 mm (1-inch) turbine
  • Bypass Valve, Model 1265: Thermoplastic, 1-inch flow path
  • Bypass Fitting Kits: Available in Copper, CPVC, Plastic NPT or BSPT, and Stainless steel NPT or BSPT pipe adapters (various sizes).
  • Brine Refill Controls: 0.33 gpm (1.25 Lpm) fixed; 0.74 gpm (2.8 Lpm) fixed; 1.3 gpm (4.92 Lpm) fixed.

Injector Performance (Logix Series Controllers)

  • New injectors for high-efficiency regeneration sequence are standard with Logix Controllers.
  • Actual injector performance is dependent on the resin used, tank geometry, elevated drain, etc. Data taken using an empty tank (no resin).
  • See the official PDF for exact tabulated values for Injectors "H", "J", "N", "R", "Q", "K", and "L" across various tank sizes.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.