Datasheet summary
Fleck 3150
Engineering summary from PDF text extraction for Fleck 3150. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product Line: Pentair Control Valves
- Model: Fleck 3150 Industrial Valve
Operating Specifications
- Material: Brass
- Hydrostatic pressure: 20 bar
- Working pressure: 1.8 - 8.5 bar
- Working temperature: 1-43 °C
- Electrical rating: 24 V - 50 Hz, other upon request
- Protection index: IP 44
- Continuous flow (Δp = 1 bar):
- Top Mount (TM): 22 m³/h
- Side Mount (SM): 23 m³/h
- Peak flow (Δp = 1.8 bar):
- TM: 28 m³/h
- SM: 29 m³/h
- Maximum backwash (Δp = 1.8 bar):
- TM: 24 m³/h
- SM: 25 m³/h
- Cv* (valve alone): 24.8 gpm (at 0.07 bar pressure drop)
Feed Water
- Regeneration types:
- Timeclock: 7 or 12 days
- Meter delayed or immediate
- Electronic timer
- Optional brining: Upflow
Valve Specification
- Regeneration cycles:
- Down Flow: Backwash, Brine & slow rinse, Rapid rinse, Brine tank refill, Service
- Upflow: Backwash, Brine & slow rinse, Rapid rinse, Brine tank refill, Service
- Meter accuracy range (± 5%): 16.67 - 568 Lpm
- Standard capacity range: 5 - 75 m³
- Extended capacity range: 25 - 375 m³
- No water during regeneration (NBP): Yes
Mechanical / Hydraulic
- Inlet / outlet connections: 2 inches BSP
- Distributor tube: 63 mm (DN 50)
- Riser tube cut: Target: 0.25 inch below tank; Max: Flush with top tank; Min: 1 inch below top tank
- Drain line connection: 2 inches BSP
- Brine line connection: 1 inch NPT
- Mounting base (top): 4 inches - 8 thread UN
- Height (from top of tank): 254 mm
- Recommended tank size application:
- Water softener:
- TM: 24 - 42 inches
- SM: 24 - 60 inches
- Filters: 24 - 42 inches (610 - 1070 mm)
- Water softener:
Options
- Mounting: Side mount available
- Control: Electronic timer
- Application: Filter, Hot water (65°C meter / 82°C timeclock)
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.