Datasheet summary
Fleck 9000
Engineering summary from PDF text extraction for Fleck 9000. Verify every value with the OEM datasheet.
Summary
Product Identification
Fleck Twin Valve Serie 9000
Features
- Continuous soft water supply; one tank in service while the second is regenerating or on standby.
- Regeneration performed using softened water.
- Valve body constructed from brass, allowing for an optional hot water configuration up to 65°C.
- Adjustable regeneration cycles.
- Fast connection available for a second tank (ordered separately).
- Supports upflow regeneration.
Technical Specifications
- Material: Brass
- Hydrostatic Pressure: 20 bar
- Working Pressure: 1.8 - 8.5 bar
- Working Temperature: 1 - 43 °C
- Electrical Rating: 24 V / 50 or 60 Hz
- Protection Index: IP 22
- Certificates: 2004/108/CE, 2006/95/CE, D.M. 174/04
Flow Rates
| Flow Rate Description | @ Pressure Drop | ¾ inch | 1 inch |
|---|---|---|---|
| Continuous (Cv*) | 0.07 bar | 4.8 gpm | 5.1 gpm |
| Continuous | 1 bar | 4 m³/h | 4.7 m³/h |
| Peak | 1.8 bar | 5.4 m³/h | 6.3 m³/h |
| Maximum Backwash | 1.8 bar | 1.9 m³/h | 1.9 m³/h |
*Cv: Flow rate of valve alone in gpm at 0.07 bar pressure drop.
Valve Specifications
- Mechanical Cycles: Adjustable
- Electronic Cycles: Adjustable
- Time Available: 164 min (Mechanical) / 199 min each cycle (Electronic)
- Regeneration Type: Downflow / Upflow
Connections
- Inlet / Outlet: ¾ or 1 inch BSP
- Distributor Tube: 26.7 mm (1 inch)
- Drain Line: ½ inch
- Brine Line 1600: ⅜ inch
- Mounting Base: 2 ½ inches - 8 NPSM
- Height (from top of tank): 165 mm
Tank Application
- Recommended Tank Diameter (Water Softener): 6 - 16 inches (150 - 400 mm)
Regeneration Cycles (Sequence Example)
- Backwash (Upflow) / Brine and Slow Rinse (Downflow)
- Brine and Slow Rinse (Upflow) / Backwash (Downflow)
- Rapid Rinse (Downflow) / Rapid Rinse (Downflow)
- Brine Tank Refill
- Service
Meter
| Parameter | ¾ inch | 1 inch |
|---|---|---|
| Accuracy Range (± 5%) | 1 - 57 Lpm | 2.6 - 151 Lpm |
| Standard Capacity Range | 0.5 - 8 m³ | 1 - 20 m³ |
| Extended Capacity Range | 2.5 - 40 m³ | 5 - 100 m³ |
Dimensions
- Regeneration: Upflow / Downflow
- Control Type: Electronic (ET, SXT)
- Hot Water Option: Up to 65°C
- By-pass Valve: Available for ¾ inch valve
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.