
Datasheet summary
Fleck 9100
Engineering summary from PDF text extraction for Fleck 9100. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product Line: Fleck 9100 Twin Valve Serie
- Type: Water Purification Valves
Technical Characteristics
Operating Specifications
- Material: PPO* (Polyphenylene oxide)
- Hydrostatic Pressure: 20 bar
- Working Pressure: 1.8 - 8.5 bar
- Working Temperature: 1 - 43 °C
- Electrical Rating: 24 V / 50 or 60 Hz, other upon request
- Protection Index: IP 22
- Certificates:
- 2004/108/CE, Electromagnetic compatibility
- 2006/95/CE, Low voltage
- D.M. 174/04, Italian norm
Flow Rate (3.5 bar inlet - valve alone)
| Connection Size | Continuous (Δp = 1 bar) | Peak (Δp = 1.8 bar) | Cv* (gpm) | Maximum Backwash (Δp = 1.8 bar) |
|---|---|---|---|---|
| ¾ inch | 4 m³/h | 5.4 m³/h | 4.8 gpm | 1.9 m³/h |
| 1 inch | 4.5 m³/h | 5.9 m³/h | 5.2 gpm | 1.9 m³/h |
* Cv: Flow rate of valve alone in gpm at 0.07 bar pressure drop.
Valve Specifications
- Regeneration: Down Flow
- Cycles: Mechanical (Adjustable), Electronic (Adjustable)
- Time Available: 164 min (Mechanical), 199 min each cycle (Electronic)
Valve Connections
- Inlet / Outlet: ¾ or 1 inch BSP
- Distributor Tube: 26.7 mm (1 inch)
- Drain Line: ½ inch
- Brine Line 1600: ⅜ inch
- Mounting Base: 4 inches - 8 NPSM
- Height (from top of tank): 185 mm
- Tank Size Application (recommended): Water softener, 6 - 16 inches (150 - 400 mm)
Meter
- Accuracy Range (± 5%):
- ¾ inch: 1 - 57 Lpm
- 1 inch: 2.6 - 151 Lpm
- Standard Capacity Range:
- ¾ inch: 0.5 - 8 m³
- 1 inch: 1 - 20 m³
- Extended Capacity Range:
- ¾ inch: 2.5 - 40 m³
- 1 inch: 5 - 100 m³
Options
- Regeneration: Upflow
- Electronic Control: ET, SXT
- Mixing: Yes
- By-pass: Valve 3/4 inch
Features
- Continuous soft water provision with only one tank in use, the other being in regeneration or stand-by.
- Regeneration with softened water.
- Valve body in PPO, corrosion-proof.
- Fast connection of the second tank, with connecting pipes in PVC delivered with the valve.
- Optional: upflow regeneration.
Disclaimer: This extracted summary may not include all figures, footnotes, or revisions. Contractual data must always match the official OEM PDF revision used for the specific project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.