Datasheet summary
Fleck NXT2 Controller
Engineering summary from PDF text extraction for Fleck NXT2 Controller. Verify every value with the OEM datasheet.
Summary
Product Identification
Product: Fleck NXT2 Controller Product Line: Pentair Control Valves Document: Fleck NXT2 Controller Spec Sheet
Features and Benefits
- On-screen multilingual support (English, Français, Deutsch, Italiano, Español, Nederlands, Português)
- Time-of-day super capacitor backup for 12-hour power loss
- 2 to 4 line scrolling text OLED display with high contrast for readability in low light and at a distance
- Full functional user interface with easy programming and bi-directional menu navigation
- Network capability for two to eight valves via CAT5 or better cables
- LED Status Indicator:
- Blue: In Service
- Flashing Blue: Regeneration Queued
- Green: Regeneration
- Flashing Green: Standby
- Red: Error condition present
- Two programmable auxiliary relay outputs (Time-based, Volume based, Alarm-based, Cycle-based, Standby)
- Remote input (Remote Lockout, Remote Regeneration)
- Easy installation with plug-in wiring harnesses
- Assistance Name and Phone Number contact fields
- Error Log History
- Water Usage Daily tracking (up to 13 weeks)
- Push Settings feature
- Capacitive Touch buttons
- Two Regeneration Lockout Windows
- Ability to reset to factory default settings or load from savable custom settings
- Full calendar display
- Master Programming Lockout (Code-based, Time-based, Delayed)
- Icons for easy system status identification
- Dynamic network addressing
- Diagnostics:
- Real-time Flow Rate
- Peak Flow Rate (resettable)
- Totalizer (resettable)
- Reserve Capacity
- Use Since Last Regeneration
- Last Regeneration date
- Identifiable Software Version
- Total Number of Regenerations
- Regeneration Interval
- Last Settings Change date
- Error Log History
- Average Daily Usage (per weekday, 3-month history)
Valve Specifications
Valve Type:
- 2750
- 2850
- 2900s
- 3150
- 3900
- 2815
Regeneration Type (applicable to System Types 4, 5, 6, 7, 8, 9, 14):
- Meter Delayed Fixed Reserve
- Meter Immediate
- Remote Signal Start Immediate
- Time Clock Delayed
Regeneration Type (media flow):
- Downflow
- Upflow Fill First
- Upflow Brine First
Electrical Rating
- 24V DC Power Supplies
- 100V-240V AC input; 24V DC output
Generic Meter Guidelines
- Open collector output
- Pulse rate generated must not exceed 100 pulses per second (100Hz) or 6,000 pulses per minute
- Support for meter outputs in the range of 1-255 gallons (25.5m³) for every 1-255 pulses
- Meter must operate at 5 VDC
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)