Back to Pentair Control Valves
Pentair logo

Datasheet summary

SIATA V132

Engineering summary from PDF text extraction for SIATA V132. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product Name: SIATA RESIDENTIAL VALVE V132
  • Product Line: SIATA WATER PURIFICATION VALVES
  • Document Title: SIATA RESIDENTIAL VALVE V132 TECHNICAL SHEET

Technical Characteristics

  • Flow rate: up to 7 m³/h (7.32 gpm)
  • Features:
    • Quick connect clips for easy installation and maintenance
    • Compatible with the entire SIATA controller range
  • Typical applications:
    • Softening
    • Demineralisation
    • Filtration
  • Optional Functions:
    • Mixing device (for residential softeners up to 800 L/h flow rate, for pressure vessels up to 10x35 inches diameter)
    • Backwash flow control (for filter and demineralisation installations)
    • Driver replica of the pressure point (for special applications, e.g., driving an external brine valve or closing the valve outlet)

Flow Rate

  • Continuous (Δp = 1 bar): 7.0 m³/h (7.32 gpm)
  • Maximum backwash (Δp = 1.8 bar): 3.0 m³/h
  • Flow rate reference (3.5 bar inlet - valve alone): See the official PDF for exact tabulated values.

Valve Specifications

  • Material: Glassfiber reinforced ABS
  • Hydrostatic pressure: 22 bar
  • Working pressure: 1.5-6 bar
  • Working temperature: 5–40°C

Dimensions

  • Inlet/outlet: Male 2 inches BSP or various QC** fittings
  • Distributor pilot: 32 mm O.D.
  • Drain line: 20 mm - QC**
  • Brine line: 3/8 inch
  • Mounting base - Top: 21/2 inches 8 NPSM
  • Height (from top of tank): 129 mm ± 2

Tank Size Application (Recommended)

  • Water softener: 8–16 inches (max 200 L of resin)
  • Filter: 8–16 inches (according to filter media specs)
  • Demineralisation: 8–16 inches (max 200 L of resin)

Meter

  • Accuracy range 3/4 inch (± 5%): 12-150 Lpm
  • Accuracy range 11/2 inch (± 5%): 36-200 Lpm

Regeneration Cycles

  • Softener & demineralisation:
    1. Backwash (Upflow)
    2. Brine & slow rinse (Down flow)
    3. Rapid rinse (Down flow)
  • Filter:
    1. Backwash (Upflow)
    2. Rapid rinse (Down flow)

Options

  • Mixing: Yes
  • Backwash Flow Control: Yes
  • Driver replica: Yes

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.