Back to Pentair Control Valves
Pentair logo

Datasheet summary

SIATA V230

Engineering summary from PDF text extraction for SIATA V230. Verify every value with the OEM datasheet.

Summary

Product identification

  • Product: SIATA COMMERCIAL VALVE V230
  • Application: Water Purification Valves - SIATA

Operating limits

  • Hydrostatic pressure: 22 bar
  • Working pressure: 1.5-6 bar
  • Working temperature: 5-40°C

Flow rates

  • Continuous flow rate (Δp = 1 bar): 8.5 m³/h
  • Peak flow rate (Δp = 1.9 bar): 11 m³/h
  • Cv (Flow rate of valve alone in gpm at 0.07 bar pressure drop): 9.6 gpm
  • Maximum backwash flow rate (Δp = 1.9 bar): 4 m³/h
  • Maximum rapid rinse flow rate (Δp = 1.9 bar): 4.5 m³/h

Feed water / Application

  • Suitable for: simplex, duplex or multiplex softening systems, filtration, demineralisation, dealkalisation, or iron & manganese removal applications.
  • Tank size application (recommended):
    • Softener & Demineralisation: 8–21 inches (max 300 L of resin)
    • Filter: 8–21 inches (according to filter media specs)

Product water / Meter options

  • Internal turbine option: for meter control
    • Accuracy range (± 5%): 12–200 Lpm
  • External meter option:
    • Accuracy range 3/4 inch (± 5%): 10–120 Lpm
    • Accuracy range 1 1/2 inch (± 5%): 12–200 Lpm

Regeneration cycles

  • Adjustable cycles: Depending on controller fitted
  • Typical cycles:
    • Softener & Demineralisation: 1) Backwash (Upflow), 2) Brine & slow rinse (Down flow), 3) Rapid rinse (Down flow)
    • Filter: 1) Backwash (Upflow), 2) Rapid rinse (Down flow)

Mechanical / hydraulic

  • Actuation: Hydraulically actuated
  • Material: Glassfiber reinforced ABS
  • Color: Blue or black
  • Connections:
    • Inlet/Outlet: male 2 inches BSP threaded
    • Distributor pipe: DN 50
    • Drain line: 20 mm - Quick connect (QC)
    • Brine line: 3/8 inch BSP
    • Mounting base: 4 inches BSP threaded
  • Dimensions:
    • Height (from top of tank): 129 mm ± 2
  • Features:
    • Quick connect clips allowing easy installation and maintenance
    • Driver replica for special applications (e.g., driving an external brine valve or closing the valve outlet)
    • Compatible with the entire SIATA controller range
    • Remote Bypass w/ or w/o sample tap: Yes

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.