SIATA V250
Engineering summary from PDF text extraction for SIATA V250. Verify every value with the OEM datasheet.
Summary
Product identification
- Product: SIATA V250 Control Valve
- Type: Water Purification Valve
- Manufacturer: Pentair Control Valves (implied by document context)
Technical Specifications
- Versions: Available with or without by-pass.
- Mounting: Top mounted valve.
- Flow Rate: Up to 21 m³/h.
- Connections: Quick pilot connections.
- Applications: Suitable for residential and commercial softening, demineralisation, dealkalisation applications, as well as filtration systems.
- Compatibility: Compatible with most of the SIATA controller range.
Technical Characteristics
- Material: ABS + 17% glass fiber.
- Color: Blue / black.
- Hydrostatic Pressure: 22 bar.
- Working Pressure: From 1.5 to 6 bar.
- Working Temperature: From 5° to 40°C.
Flow Rate (3.5 bar inlet - valve alone)
- Continuous (∆p = 1 bar): 21 m³/h
- Peak (∆p = 1.9 bar): 28.9 m³/h
- *Cv : 24.4
- *Cv: Flow rate of valve alone in GPM at 0.07 bar pressure drop.
- Maximum Backwash (∆p = 1.9 bar): 12 m³/h
- Maximum Rapid Rinse (∆p = 1.9 bar): 15 m³/h
Valve Connections
- Inlet / Outlet: 2”¼ - BSP male threaded.
- Drain line connector: 1’’1/2 BSP female - 2’’ BSP male.
- Mounting base / Tank connection: 4” top mount.
- Adjustable cycles: Depending on controller fitted.
Options
- Threaded fittings:
- 494-A/05: dia. 50 mm to glue (PVC-PVC)
- 494-G/05: 2” BSP male (Brass-Brass)
- 494-H/05: 1 ½” BSP female (PVC-PVC)
- 494-P/05: 1 ½” BSP female (Brass-Brass)
- Regeneration: Up flow regeneration - No.
- Duplex systems: Yes.
- External DLFC 1” 1/4: Yes.
Tank Size Application (Recommended)
- Softener & Demineralisation: 14’’ - 30’’ (max 500 L of resin).
- Filter: 14’’ - 30’’ (according to filter media specs).
Regeneration Cycles
- Softener:
- Backwash (Up flow)
- Brine & slow rinse (Down flow)
- Rapid rinse (Down Flow)
- Filter:
- Backwash (Up Flow)
- Rapid rinse (Down Flow)
- Demineralisation:
- Backwash (Up flow)
- Brine & slow rinse (Down flow)
- Rapid rinse (Down Flow)
Note: For filter applications, depending on the controller type, brine draw and slow rinse time must be set to 0.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.