Datasheet summary
SIATA V360
Engineering summary from PDF text extraction for SIATA V360. Verify every value with the OEM datasheet.
Summary
Product Identification
- Product: SIATA V360 - INDUSTRIAL VALVE
- Product Line: Pentair Control Valves
- Type: Side mounted valve for water purification applications
Technical Specifications
- Applications: Industrial softening, demineralisation, dealkalisation, and filtration systems.
- Flow Rate: Up to 32 m³/h (continuous, at 1 bar pressure drop).
- Peak Flow Rate: 42 m³/h (at 1.9 bar pressure drop).
- Maximum Backwash Flow Rate: 15 m³/h (at 1.9 bar pressure drop).
- Maximum Rapid Rinse Flow Rate: 18 m³/h (at 1.9 bar pressure drop).
- Cv (Valve alone at 0.07 bar): 36.8 GPM.
- Pistons: High flow rate pistons for improved performances.
- Controller Compatibility: Compatible with most of the SIATA controller range.
- Regeneration: Supports Up Flow regeneration.
- System Type: Suitable for Duplex systems.
- External DLFC: Yes, 1” 1/4.
Technical Characteristics
- Inlet / Outlet Connection: Up to 3” flanged – threaded or to be glued.
- Specific options include: 1” ½ BSP, 2” BSP, 2” ½ BSP, 3” BSP, ISO 50 GLUED, ISO 63 GLUED, ISO 75 GLUED, Ø 60.4 GLUED, 3” NPT GLUED, 3” BSP.
- Drain Line Connector: 40 mm ISO – molded in outlet body.
- Mounting Base / Tank Connection: Side mount / flanged.
- Adjustable Cycles: Depending on the controller fitted.
- Material: Glassfiber reinforced ABS.
- Color: Blue or black.
- Hydrostatic Pressure: 22 bar.
- Working Pressure: 2 to 6 bar.
- Working Temperature: 5 to 40°C.
Tank Size Application (Recommended)
- Softener & Demineralisation: 24” - 48’’ (max 1200 l of resin).
- Filter: 24” - 48” (according to filter media specs).
Options
- Connections for cylinder opening/closure (top and bottom columns).
- Connection for brine draw Ø 1”.
- Connection for male drain Ø ISO 40.
- Connection for pilot timer control.
Regeneration Cycles
- Filter:
- Backwash (Up Flow)
- Rapid rinse (Down Flow) (Note: Depending on controller type, brine draw and slow rinse time must be set to 0).
- Softener & Demineralisation:
- Backwash (Up flow)
- Brine & slow rinse (Down flow)
- Rapid rinse (Down Flow)
Disclaimer: Extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.