Back to Pentair Water Softeners
Pentair logo

Datasheet summary

Fleck 2750

Engineering summary from PDF text extraction for Fleck 2750. Verify every value with the OEM datasheet.

Summary

Product identification

  • Model: 2750
  • Type: 1" Control Valve
  • Part No.: 40737 Rev B

Features

  • Suitable for large residential/light commercial applications
  • Fully adjustable, 5-cycle control (upflow backwash, downflow brining and slow rinse, rapid rinse, timed brine refill, and downflow service)
  • Backwash capacity handles tanks up to 24" diameter
  • Solid, lead-free brass valve body
  • Hydraulically-balanced piston, seal, and spacer design

Options

  • Filter or softener control valves
  • Hot water operation:
    • Up to 150°F for 1700 brine system or metered control valve
    • Up to 180°F for 1600 brine system or metered control valve
  • Manual operation (filter or softener)
  • Service valve operator
  • No hard water bypass
  • Electronic timer (SXT, XT, 3214NXT, or 3200NXT)
  • Environmental cover
  • Auxiliary switches
  • Meter delayed or immediate initiated regeneration

Valve Specifications

  • Valve material: Lead-free brass
  • Inlet/Outlet: 1" NPTM
  • Cycles: 5
  • Flow Rates (50 psi Inlet) - Valve Alone:
    • Continuous (15 psi drop): 26 GPM
    • Peak (25 psi drop): 33 GPM
    • Cv (flow at 1 psi drop): 6.8
    • Max. backwash (25 psi drop): 25 GPM
  • Regeneration: Downflow only
  • Adjustable cycles: Yes
  • Time available per cycle:
    • Electromechanical: 164 minutes
    • SXT: 199 minutes
    • NXT: 240 minutes
    • XT: 240 minutes

Meter Information

  • Meter accuracy:
    • 0.75" - 0.25 - 15 GPM: +/- 5%
    • 1" - 0.7 - 40 GPM: +/- 5%
  • Meter capacity range (gal.):
    • Standard: 310 - 5,270
    • Extended: 1,550 - 26,350
    • SXT: 1 - 999,900
    • NXT: 9,900,000
    • XT: 1,000 - 9,900,000

Mechanical / Hydraulic

  • Distributor pilot: 1.05" O.D.
  • Drain line: 3/4" NPTM
  • Injector brine system:
    • 1600 & 1050: 3/8"
    • 1700 & 1710: 1/2"
  • Brine line: 3/8" & 1/2"
  • Mounting base: 2-1/2" - 8 NPSM
  • Height from top of tank: 6-1/2"

Typical Applications

  • Water softener tanks: 10" - 24" diameter
  • Filter tanks: 10" - 21" diameter

Electrical

  • Power rating: 24 v, 110 v, 220 v - 50 Hz, 60 Hz
  • Transformers (24 VAC Pentair):
    • 115 VAC +/- 20% Input, 24 VAC Output
    • 230 VAC +/- 20% Input, 24 VAC Output

Operating Limits

  • Working pressure: 20 - 125 psi
  • Hydrostatic pressure: 300 psi
  • Temperature: 34° - 110°F

Additional Information

  • Estimated shipping weight:
    • Time clock valve: 13 lbs.
    • Metered valve: 26 lbs.

Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.

Official datasheet (PDF)

Lenntech datasheet mirror

Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.