
Datasheet summary
Fleck 2850 S
Engineering summary from PDF text extraction for Fleck 2850 S. Verify every value with the OEM datasheet.
Summary
Product identification
- Model: 2850s
- Type: 1.5" Control Valve
- Part No.: 42366 Rev D
Features
- 1.5" commercial valve with best-in-class flow rates
- Multi-tank system capability
- Increased service and backwash flow
- Fully adjustable 5-cycle control:
- Controlled upflow backwash
- Downflow brining and slow rinse
- Rapid rinse
- Timed brine refill
- Downflow service
- Time-tested, hydraulically-balanced piston, seal and spacer design
- Solid lead-free brass* valve body
- 1.5" top mount control valve for smaller commercial/industrial applications
- Backwash capacity suitable for up to 36" diameter tanks (softeners)
- Suitable for filter applications up to 30" diameter tanks
- Consistent brining with timed brine refills
- Choice of 7- or 12-day clock, manual or volume initiated timers
Options
- Meter-initiated regeneration
- Time Clock
- No untreated water bypass piston
- Environmental cover
- Control types: Electromechanical, SXT, or NXT
- Hot water operation (time clock up to 180°F; metered valve up to 150°F)
- Manual operation
- Service valve operator
- Auxiliary micro switch
- Side mount configuration
- Cold water operation (up to 100°F)
Valve Specifications
- Valve material: Lead-free brass*
- Inlet/Outlet: 1-1/2" NPTF
- Cycles: 5
- Flow Rates (50 psi Inlet) - Valve Alone:
- Continuous (15 psi drop): 70 GPM (side mount/top mount)
- Peak (25 psi drop): 90 GPM (side mount/top mount)
- Max. backwash (25 psi drop): 70 GPM
- Cv (flow at 1 psi drop): 18
- Regeneration Type: Downflow/Upflow or Downflow only
- Adjustable cycles: Yes
- Time available per cycle:
- Electromechanical: 164 minutes
- SXT: 0 - 199 minutes
- NXT: 0 - 12 hours
- XT: 0 - 12 hours
Meter Information
- Meter accuracy:
- 7/10 - 40 GPM: +/- 5% (1" meter)
- 1-1/2 - 75 GPM: +/- 5% (1-1/2" meter)
- Meter capacity range (gallons):
- 1" Standard: 310 - 5,270
- 1" Extended: 1,150 - 26,350
- 1-1/2" Standard: 625 - 10,625
- 1-1/2" Extended: 3,125 - 53,125
- NXT, XT: 1,000 - 9,900,000
- SXT: 1,000 - 60,000
Mechanical / Hydraulic
- Distributor pilot: 1-9/10" O.D.
- Drain line: 1-1/4" NPTF
- Injector brine system:
- 1600 & 1650: 3/8"
- 1710: 1/2"
- Brine line: 3/8" & 1/2"
- Mounting base: 4" - 8 UN
- Height from top of tank: 6-1/2"
Electrical
- Rating: 24 V, 110 V, 220 V - 50 Hz, 60 Hz
- Max. VA: 72
Operating Limits
- Pressure:
- Hydrostatic: 300 psi
- Working: 20 - 125 psi
- Temperature:
- Cold water: 34° - 110° F
- Hot water: Up to 180° F
Typical Applications
- Water Softener: 14" - 36" diameter tanks
- Iron Filter: 14" - 30" diameter tanks
- Sediment Filter: 14" - 30" diameter tanks
- Carbon Filter: 14" - 30" diameter tanks
- Neutralizing Filter: 14" - 30" diameter tanks
* As defined in the U.S. EPA Safe Drinking Water Act; the product also meets California Proposition 65 Standards.
Disclaimer: This extraction may miss figures, footnotes, or revisions. Contractual data must match the OEM PDF revision used on the project.
Official datasheet (PDF)
Curated from selected public technical reference material for discovery and preliminary comparison. This summary is not a substitute for a current certified manufacturer datasheet. Verify revisions and design limits before use.